Opticon
OPR 2001
Specifications Manual
37
14. Reliability
MTBF (Mean Time Between Failures) of this product is 10,000 hours.
The estimate of MTBF is based on standard operation of the product within the recommended
temperature range and without extreme electronic or mechanical shock.
15. Auto Trigger (Option)
The product has an optional auto trigger setting, which starts barcode reading automatically by
using sensor detection. The scanner starts barcode reading after detecting reflection from the
surface when the auto trigger is used.
Auto trigger distance: 50 ±10 mm from the edge of the scanner.
Conditions
Moving Speed: 100 ±10 mm/s (the moving direction is not specified)
Angle: Skew angle, excluding Pitch Angle and Dead Zone, specified
in section 7.3 Pitch, Skew and Tilt.
Environmental Temperature and
Humidity:
Room temperature and humidity
Environmental Illuminance: 500 to 900 lx
Conditions for the auto trigger: 1. Barcode sheet: OPTOELECTRONICS Test Sheet (white)
Background: OPTOELECTRONICS Test Sheet (black)
2. Barcode sheet: OPTOELECTRONICS Test Sheet (black)
Background: OPTOELECTRONICS Test Sheet (white)
Figure 28: Auto trigger operation