b)BUSY/READY

The scanner and the host computer notify each other of their state and whether they can receive data with BUSY/READY through an RTS line. They can communicate state to each other through a CTS line when connected as in the following figure.

Figure 12: Busy/Ready communication

The scanner stays ON (is able to receive data) except during certain parts of the process, such as receiving data (buzzer command execution), transmitting data, and menu processing. The scanner checks the CTS line before transmitting data. When it is ON, the scanner transmits data. When it is OFF, the scanner waits for it to turn ON within a set time. The scanner will abort transmission with an error indication (buzzer) when the CTS line is not ON within a specified period. The Flow Control time-outs are as follows, and the default setting is “indefinitely“ (I0).

Flow Control Time Out

Menu/Command

 

 

Indefinitely

I0

 

 

100 ms

I1

 

 

200 ms

I2

 

 

400 ms

I3

 

 

Figure 13: Cannot receive command

21

Page 21
Image 21