Manual No.
Setting the Number of
Characters to be Scanned
ZZ | Start/End | [[ | ||
Program | ||||
|
|
| ||
| Menu |
|
| |
|
|
|
| |
H0 | Fixed length | I1 |
| |
OFF | % | |||
|
| |||
| all codes |
| ||
|
|
| ||
|
|
|
| |
H1 | Fixed length | I2 |
| |
ON |
| |||
|
|
| ||
| all codes |
|
| |
|
|
|
| |
HK | Fixed length | IL |
| |
ON |
| |||
| selected codes |
|
| |
|
|
|
| |
HL | Min. length | IM | ||
selected codes | ||||
|
|
|
| |
HM | Max. length | IN | ||
selected codes | ||||
|
|
|
|
Setting Code Specific Options - Options for specific codes may be configured affecting:
*Enabling and disabling code variants and translations.
*Data verification such as by mean of a check digit calculation. A check digit has a value that can be calculated from the other data characters and is usually the last data character in a bar code.
*
The more common options are described here.
Check CD - Enables the check digit calculation. If the calculated check digit does not correspond to the check digit in the bar code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code.
Do Not Check CD - Disables the check digit calculation. This option is required when the bar codes do not contain a check digit or contain an invalid check digit.
Transmit CD - Enables the transmission of the check digit together with the data characters. If the check digit calculation is disabled, the reader cannot differentiate anymore between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, including what could constitute a check digit.
Do Not Transmit CD - Disables the transmission of the check digit. If the check digit calculation is disabled, the reader cannot differentiate between a (valid) check digit and a data character. It will therefore transmit all data characters of the able, excluding the character that could constitute the check digit for the type of bar code.
Transmit ST/SP - Enables the transmission of the start and stop characters of a bar code.
Do Not Transmit ST/SP - Disables the transmission of the start and stop characters of a bar code.