Manual No. | Series LGP Handheld CCD Scanner |
Codabar Settings (continued)
String format:
start | data (1+ | check | data (1+ | check | stop |
char. | chars.) | digit | chars.) | digit | char. |
String format:
start | data (1+ | check | data (1+ | check | stop |
char. | chars.) | digit | chars.) | digit | char. |
Options for Codabar:
*Enable ABC code concatenation.
*Enable CD code concatenation.
*Enable check digit check.
*Disable transmission of the check digit.
*Disable transmission of start/stop.
*Selection of start/stop character translation.
*Selection of minimum number of data characters.
*Enable library space (CLSI) insertion.
*
Space insertion - This option inserts spaces in position 2, 7 and 13 of the data string for use in library systems.
ST/SP translation - This option enables the translation and transmission of the start and stop characters. Thus, if the option ST/SP: abcd/tn*e is chosen, the start character is converted to lower case, e.g. from A, B, C or D to a, b, c or d, respectively), and the stop character is converted from A, B, C or D to t, n, * or e, respectively.
Minimum data characters - Codabar labels are checked for a minimum of 1, 3 or 5 characters as set by the user. If the number of characters in the label is shorter than the minimum selected, the label will be rejected. If the fixed length option is used for Codabar type labels, then such labels will additionally be checked for fixed length. This option will no longer be supported in future software releases.
Intercharacter gap check - This option enables the reading of Codabar labels with a large or irregular gap between characters.
Page 27