Manual No. 25-ULGPMU01-01Series LGP Handheld CCD Scanner

MSI/Plessey Settings

ZZ

Start/End

[[ ￿

￿

Program

 

Menu

 

 

 

 

 

 

 

 

4A

Do not

5B

￿

 

check CD

 

 

 

 

 

%

4B

Check 1 CD =

5C

￿

Mod 10

 

 

 

 

 

4C

Check 2 CD's

%D ￿

 

= Mod 10

 

 

/Mod 10

 

 

 

 

 

 

 

 

4D

Check 2 CD's

5E

￿

 

= Mod 10

 

 

 

 

 

 

/Mod 11

 

 

 

 

 

 

 

%

4E

Transmit CD1

5F

￿

 

 

 

 

 

4F

Transmit CD1

5G

￿

 

and CD2

 

 

 

 

 

 

4G

Do not

5H

￿

 

transmit CD

 

 

 

 

 

 

4R

Check 2 CD's

5S

￿

 

= Mod 11

 

 

 

 

 

 

/Mod 10

 

 

 

 

 

 

 

 

MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable start/stop characters. Supported characters include numeric digits 0 through 9.

The checksum is calculated as the sum modulo 10 or 11 of the data characters. The checksum CD2 is calculated as the sum modulo 10 or 11 of the data characters and CD1.

String format:

data (1 to

CD1

CD2

13 digits)

 

 

Options for MSI/Plessey:

*Disable check digit check.

*Selection of the check digit calculation.

*Selection of the number of check digits to be transmitted.

Check digit - If the check digit calculation is required, then the appropriate calculation method must be selected. Do not transmit CD - The character positions CD1 and CD2 are not transmitted.

Transmit CD1 - The character position CD2 is not transmitted. Transmit CD1 and CD2 - All characters in the label are transmitted.

Page 30