Read Mode Settings
ZZ | Start/End | [[ |
|
Program |
| ||
|
|
| |
| Menu |
|
|
|
|
|
|
S0 | Single | T1 |
|
read |
| ||
|
|
| % |
S1 | Multiple | T2 | |
read | |||
|
|
|
|
S2 | Continuous | T3 |
|
read |
| ||
|
|
|
|
XA | YB |
| |
wait mode |
| ||
|
|
| |
| disabled |
|
|
|
|
|
|
XB | TC |
| |
wait mode |
| ||
|
|
| |
| 0.25 sec. |
|
|
|
|
|
|
XC | YD | % | |
0.50 sec. | |||
| wait mode |
|
|
|
|
|
|
XD | YE |
| |
wait mode |
| ||
|
|
| |
| 0.70 sec. |
|
|
|
|
|
|
Single Read - When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again to read another label. This option and "Disable trigger" cannot be programmed at the same time.
Multiple Read - When a bar code has been decoded, the reader will stay ON for a time as set by "read time settings" or indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the label has not been detected for a number of scans.
Continuous Read - The reader will produce as much data as it can decode regardless whether it is the same or not. This mode is mainly used for demonstration and diagnosis.