TANDBERG Edge 75/85/95 MXP
290
Cable Specification RS-449 Cable to KIV-7 TANDBERG MXP and Classic Endpoints that support External Network
Connector on Tandberg End:
o Female 26pin High Density DSUB Newark P/N 50F2055 or Equivalent
Connector on RS-449:
o DSUB 37 pin Male
Signal Name Female
26pin DSUB
(Tandberg end)
Pin Number
Male
37pin DSUB
(DCE end)
Pin Number
Comments
Frame Ground 1 1 Do not connect shield to FGND
Send Data (A)
Send Data (B)
11
12
4
14
Twisted Pair
Send Timing (A)
Send Timing (B)
17
18
15
12
Twisted Pair
Receive Data (A)
Receive Data (B)
13
14
3
16
Twisted Pair
Receive Timing(A)
Receive Timing (B)
15
16
17
9
Twisted Pair
LOS 25 31
Signal Ground 19 1
4,20,28
19,23,27
Jumpers
Jumpers