Setup menu list (continued)SCENE FILE screen (continued)

Item

Display

 

Description of settings

mode

 

 

 

 

 

 

DETAIL LEVEL

(Camera)

Adjusts the level of the image outline correction (in the horizontal and vertical directions).

 

 

-7…0…+7
V DETAIL

(Camera)

Adjusts the level of outline correction in the vertical direction.

LEVEL

 

-7…0…+7

DETAIL

(Camera)

Adjusts the level of noise reduction of the detail signal.

CORING

 

Set to – for a clearer image. Noise increases slightly.

 

 

Set to + to reduce noise.

 

 

-7…0…+7

CHROMA

(Camera)

Adjusts the chroma level.

LEVEL

 

-7…0…+7

CHROMA

(Camera)

Adjusts the chroma level.

PHASE

 

-7…0…+7

COLOR TEMP

(Camera)

Make fine adjustments to the color temperature (after white balance Ach adjustment).

Ach

 

-7…0…+7

COLOR TEMP

(Camera)

Make fine adjustments to the color temperature (after white balance Bch adjustment).

Bch

 

-7…0…+7

MASTER PED

(Camera)

Adjusts the master pedestal (black level of the image) as the basis for images.

 

 

-15…0…+15
A.IRIS LEVEL

(Camera)

Sets the desired AUTO IRIS level.

 

 

-6…0…+6
DRS

(Camera)

Selects the DRS (Dynamic Range Stretcher) function. It enables the dynamic

 

 

range to be expanded by compressing the level of the video signals in the high-

 

 

brightness areas where overexposure results during normal shooting.

 

 

OFF, 1, 2, 3

 

 

• The higher the number of the setting, the higher the compression level of the

 

 

high-brightness areas.

 

 

• The higher the number of the setting, the greater the interference in darker areas.

GAMMA

(Camera)

Selects the gamma curves.

 

 

HD NORM: This gamma setting is suitable for HD shooting.

 

 

LOW:

Makes a mellow image using the gamma curve that has a gentle

 

 

 

incline in low-brightness curve. The contrast sharpens.

 

 

SD NORM: This is the normal video setting carried over from the DVX100 series.

 

 

HIGH:

Expands the tone of dark parts and makes a brighter image using the

 

 

 

gamma curve that has a sharp incline in low-brightness curve. The

 

 

 

contrast softens.

 

 

B.PRESS: Makes the contrast sharper than LOW.

 

 

CINE-LIKE D: Uses a gamma curve designed to create cinema-like images.

 

 

CINE-LIKE V: Uses a gamma curve designed to create cinema-like images with

 

 

 

emphasized contrast.

 

 

• When you select CINE-LIKE gamma, we recommend setting the lens aperture

 

 

lower than normal image level (approximately 1/2) for optimal results.

KNEE

(Camera)

To avoid overexposure, select the compression level (knee point) of the high

 

 

intensity video signals received through the image pickup device.

 

 

AUTO: Sets the level automatically according to the received signals.

 

 

LOW:

Low setting (Compression starts at approx. 80%)

 

 

MID:

Medium setting (Compression starts at approx. 90%)

 

 

HIGH: High setting (Compression starts at approx. 100%)

 

 

• Not available when a DRS value is set, or when GAMMA is set to CINE-LIKE.

indicates the factory setting.

52