TC/UB SETUP screen

Item

Display

 

Description of settings

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC MODE

(Camera)

Selects the correction mode of the internal time code when the time code of the

 

 

 

 

internal time code generator is recorded.

 

 

 

 

DF:

Uses the drop frame mode.

 

 

 

 

NDF:

Uses the non-drop frame mode.

 

 

 

 

• TC MODE is automatically set to NDF when you set recording frame rate of

 

 

 

 

recording format to 24P.

 

 

 

 

• Takes effect only when SYSTEM FREQ = 59.94 Hz. PH 1080/24P and PH

 

 

 

 

720/24P represent native recording.

 

 

TCG

(Camera)

Sets the mode in which you advance the internal time code generator.

 

 

 

 

FREE RUN: The time code is advanced regardless of the operation mode. A

 

 

 

 

 

slight time error may occur when switching to PB mode if the frame

 

 

 

 

 

rate is set to 24P.

 

 

 

 

REC RUN: The time code is advanced only when recording.

 

 

TC PRESET

(Camera)

Sets the initial time code.

 

 

 

 

Set the frame value to 0 or a multiple of 4 when you set recording frame rate

 

 

 

 

of recording format to 24P. If any other value is set, the recorded time code will

 

 

 

 

mismatch.

 

 

 

 

YES, NO

 

 

 

 

 

UB PRESET

(Camera)

Sets the user information.

 

 

 

 

YES, NO

 

 

 

 

 

 

 

 

 

 

 

EXT TC LINK

(Camera)

Synchronizes the initial time code value during multi-camera shooting. (SLAVE

 

Menu

 

 

camera time codes are synchronized to the master internal TCG value.

 

 

 

MASTER: Sets the mode to master mode.

 

 

 

SLAVE:

Sets the mode to slave mode. When the COUNTER RESET/TC

 

 

 

 

 

SET button is pressed, input time codes are synchronized to the

 

 

 

 

 

 

 

 

NO:

internal TCG.

 

 

 

 

Returns to the previous screen.

 

 

 

 

• MASTER and SLAVE mode settings are in effect only when this menu is open.

 

 

 

 

When the menu is closed, EXT TC LINK is automatically canceled.

 

 

 

 

 

 

 

indicates the factory setting.

 

57