Error/Warning Displays
If for any reason an error occurs in this monitor, the LEDs above the picture adjusting knob flash at
Error/Warning displays | Symptom | Solution |
|
|
|
Inverter error | If a malfunction occurs in the inverter that | Switch the power supply OFF once, then |
| controls the backlight brightness, the | switch it back ON again. If an error is still |
| backlight will switch OFF. | displayed, contact the vendor where you |
| The screen becomes completely black. | purchased the monitor. |
|
|
|
Fan stop | The fan in the back of the monitor stops if | Switch the power supply OFF once, then |
Error | a malfunction occurs. If a picture is being | switch it back ON again. If the error is still |
| displayed when the malfunction occurs, it | displayed after this, contact the vendor |
| will continue being displayed as is. | where you purchased the monitor |
|
| immediately. |
|
| If a fan stop error occurs, setting “FAN |
|
| MOTOR” to “OFF” in the “SYSTEM |
|
| CONFIG” menu (refer to page 21) allows |
|
| you to continue using the monitor with |
|
| reduced screen brightness. |
|
|
|
Maintenance
•To clean the cabinet or surface of the liquid crystal protection panel, gently wipe with a soft, dry cloth.
If the surfaces are extremely dirty, use a soft cloth dipped in a weak detergent solution and then
•Never use thinner or benzene to clean this unit.
Doing so would cause the surface of the monitor to become discolored, and cause paint to peel.
•Do not spray cleansers directly onto the monitor.
Water or similar substances getting inside the monitor can cause a malfunction.
Maintenance Inspections
Maintenance inspections are necessary for the user to use this equipment safely. It is important to keep monitor functions in good condition at all times through periodical and appropriate maintenance. In order to use this monitor for a long time, and to make full use of all of its functions, be sure to carry out the following maintenance inspections.
A backlight is used in the liquid crystal panel. This part (consumable) deteriorates as time passes, and can cause performance levels to drop, or may cause a malfunction.
Therefore, in addition to the
The following maintenance performance times give standard guidelines for when to perform maintenance, and do not indicate the individual lifespan of your equipment. Also, note that the deterioration time varies depending on the usage environment and way in which the equipment is used.
Part name | Quantity | Periodic maintenance | |
inspection time | |||
|
| ||
|
|
| |
Backlight |
| Replace every 50,000 | |
and liquid | 1 | hours* | |
crystal panel |
|
| |
Fan | 1 | Replace every 10,000 | |
| hours | ||
|
| ||
|
|
|
* You cannot replace just the backlight unit on its own.
34