Main Menu (continued)

g Restrictions on various FUNCTION settings

Under the following conditions, various settings are disabled.

Setting

Disabling condition

 

 

HV DELAY

In SUB WINDOW, WFM or PIXEL TO PIXEL mode, “INVALID FUNCTION” is displayed and the

 

setting is disabled.

 

When “YPBPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.”, “INVALID FUNCTION” is

 

displayed and the setting is disabled.

 

 

AUTO

When “YPBPR/RGB” set in “INPUT SELECT” menu is other than “RGB-COMP.”, “NOT RGB-

SETUP

COMP. CH” is displayed and the setting is disabled.

 

When “YPBPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.” and there is NO SIGNAL,

 

“INCOMPLETE” is displayed and the setting is disabled.

 

 

GAMMA

When GPI item is set, “INVALID FUNCTION” is displayed and the setting is disabled.

SELECT

When “YPBPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.”, “INVALID FUNCTION” is

 

displayed and the setting is disabled.

 

 

SD ASPECT

When GPI item is set, “INVALID FUNCTION” is displayed and the setting is disabled.

 

When SUB WINDOW (still picture) or HD display (including PIXEL TO PIXEL) is on, “INVALID

 

FUNCTION” is displayed and the setting is disabled.

 

 

SCAN

When GPI item is set, “INVALID FUNCTION” is displayed and the setting is disabled.

 

In SUB WINDOW or PIXEL TO PIXEL mode, “INVALID FUNCTION” is displayed and the setting

 

is disabled.

 

 

SUB

When “YPBPR/RGB” set in “INPUT SELECT“ menu is other than “RGB-COMP.”, “INVALID

WINDOW

FUNCTION” is displayed and the setting is disabled.

 

When “RGB-COMP.” is selected in SUB WINDOW with a motion picture on, the screen turns SINGLE.

 

When an item other than “RGB-COMP.” is selected, two motion pictures are displayed on the

 

screen. When a still picture is on, blackout occurs.

 

 

WFM

In SUB WINDOW or PIXEL TO PIXEL mode, “INVALID FUNCTION” is displayed and the setting

 

is disabled.

 

When “YPBPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.” or “RGB-VIDEO”, “INVALID

 

FUNCTION” is displayed and the setting is disabled.

 

 

MARKER

When “YPBPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.”, “INVALID FUNCTION” is

 

displayed and the setting is disabled.

 

When GPI item is set or in SUB WINDOW mode, “INVALID FUNCTION” is displayed and the

 

setting is disabled.

 

 

PIXEL TO

When “YPBPR/RGB” set in “INPUT SELECT” menu is “RGB-COMP.” or “RGB-VIDEO”, “INVALID

PIXEL

FUNCTION” is displayed and the setting is disabled.

 

In SUB WINDOW mode, “INVALID FUNCTION” is displayed and the setting is disabled.

 

 

PIXEL POS.

When PIXEL TO PIXEL is OFF, “PIXEL TO PIXEL OFF” is displayed and the setting is disabled.

 

When PIXEL TO PIXEL is 720P display, the position becomes CENTER.

 

When the display position is not CENTER in PIXEL TO PIXEL mode during 1080P display and

 

the 720P signal is selected, the display position moves to CENTER.

 

 

MONO

When GPI item is set, “INVALID FUNCTION” is displayed and the setting is disabled.

 

 

g Operation items displayed when a FUNCTION button is used

When any of the buttons, [FUNCTION1] to [FUNCTION5], is pressed, the following messages are displayed according to the operation assigned to the pressed button.

• HV DELAY

• MARKER

DELAY OFF, V DELAY, H DELAY, HV DELAY

MAKER OFF, 4:3 MARKER, 13:9 MARKER,

• AUTOSETUP

14:9 MARKER, VISTA MARKER,

COMPLETE: Display for completion

CNSCO MARKER, 95% MARKER, 93% MARKER,

INCOMPLETE: Display for incompletion

90% MARKER, 88% MARKER, 80% MARKER

NOT RGB-COMP. CH

• PIXEL TO PIXEL/PIXEL POSITION

• GAMMA SELECT

CENTER, LEFT TOP, LEFT BOTTOM,

GAMMA STANDARD, GAMMA FILM,

RIGHT TOP, RIGHT BOTTOM

GAMMA STDIO/PST

PIXEL TO PIXEL OFF

• SCAN

• LEVEL METER

NORMAL SCAN, UNDER SCAN

METER OFF, METER 2CH, METER 4CH,

• SUB WINDOW

METER 8CH

SINGLE, FULL/PART, STILL

 

23