Manuals
/
Panasonic
/
Household Appliance
/
Air Conditioner
Panasonic
CS-MKS18NKU APPENDIX A Operating Instructions, CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU
Models:
CS-MKS18NKU
CS-MKS9NKU
CS-MKS24NKU
1
44
118
118
Download
118 pages
59.17 Kb
41
42
43
44
45
46
47
48
<
>
Troubleshooting
Specifications
Install
Refrigerant Flow Diagram
Dimension
Wired Remote Controller
If the self-diagnostics function fails to operate
Setting procedure
How to Identify a Serial Communication Error
TIMER lamp
Page 44
Image 44
APPENDIX A Operating Instructions
CS-MKS7NKU
CS-MKS9NKU
CS-MKS12NKU
(852-6-4181-214-00-2)
A-1
Page 43
Page 45
Page 44
Image 44
Page 43
Page 45
Contents
INDOOR UNIT CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU
CS-MKS24NKU
TECHNICAL & SERVICE MANUAL
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
SAFETY PRECAUTIONS
If refrigerant gas leaks during the work, ventilate the room
Table of Contents
2. SPECIFICATIONS
4. REFRIGERANT FLOW DIAGRAM
8. TROUBLESHOOTING BEFORE CALLING FOR SERVICE
APPLICABLE MULTI-OUTDOOR UNITS
1. OPERATING RANGE
Temperature
Indoor Air Intake Temp
Outdoor Air Intake Temp
SPECIFICATIONS
Unit Specifications
Features
Dimensions & Weight
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
Features
Dimensions & Weight
Type
Voltage Rating
2-2. Major Component Specifications
2-2-1. Indoor Unit
Control PCB
Fan Motor
Indoor Unit CS-MKS9NKU
Control PCB
Fan Motor
Flap Motor
Indoor Unit CS-MKS12NKU
Control PCB
Fan Motor
Flap Motor
Indoor Unit CS-MKS18NKU
Control PCB
Fan Motor
Flap Motor
Indoor Unit CS-MKS24NKU
Control PCB
Fan Motor
Flap Motor
2-3. Other Component Specifications
Temperature F C
Temperature F C
Resistance k ohm
3. DIMENSIONAL DATA
CS-MKS9NKU CS-MKS12NKU
CS-MKS24NKU
CS-MKS18NKU
4. REFRIGERANT FLOW DIAGRAM
4-1. Refrigerant Flow Diagram
5-1. Air Throw Distance Charts
5. PERFORMANCE DATA
Indoor Unit
Cooling
CS-MKS9NKU Room air temp. 80F 26.7C
Fan speed
Cooling
Cooling
Cooling
6-1. Electric Wiring Diagrams
6. ELECTRICAL DATA
ASSY
LAMP
7. FUNCTIONS
7-1. Operation Functions
Emergency operation
SENSOR DRY
HIGH POWER
Timer backup
NIGHT SETBACK
Lamp colors
NOTE CLxx models only
7-2. Protective Functions
Freeze prevention
8. TROUBLESHOOTING BEFORE CALLING FOR SERVICE
8-1. Precautions before Performing Inspection or Repair
8-2. Method of Self-Diagnostics
PROCEDURE
INDOOR UNIT 1 OPERATION lamp 2 TIMER lamp 3 QUIET lamp
OPERATION button REMOTE CONTROL receiver
DIAGNOSIS CONTENTS
INDICATION ON INDOOR UNIT
2 If the self-diagnostics function fails to operate
No indicators illuminate and the indoor fan does not rotate
Check the power voltage Blown
Check the indoor unit Is the fuse blown?
8-3. Checking the Indoor and Outdoor Units
T-RUN Test run compressor and fan motor turn ON
3 How to Identify a Serial Communication Error
Timer
3-2 Condition E12
8-4. Trouble Diagnosis of Fan Motor
8-4-1. Indoor Fan Motor
8-5. Noise Malfunction and Electromagnetic Interference
Locations most susceptible to noise
Trouble
Correction
Page
APPENDIX A Operating Instructions
CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU
Operating Instructions Split System Air Conditioner
CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU
CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU
Model No Indoor Units
FEATURES
CONTENTS
SAFETY PRECAUTIONS
PRODUCT INFORMATION
ELECTRICAL REQUIREMENTS
INSTALLATION LOCATION
SAFETY INSTRUCTIONS
Refrigerant gas leakage may cause fire
NAMES OF PARTS
Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose
Remote Controller
Refrigerant Tubes OUTDOOR UNIT Air Outlet
UNIT DISPLAY AND OPERATION BUTTON
REMOTE CONTROLLER DISPLAY
REMOTE CONTROLLER
REMOTE CONTROLLER CONTINUED
SWEEP
USING THE REMOTE CONTROLLER
REMOTE CONTROLLER CONTINUED
USING THE REMOTE CONTROLLER CONTINUED
OPERATION WITH THE REMOTE CONTROLLER
1. Operation
3. Fan Only
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
2. Adjusting the Fan Speed
4. Night Setback Mode
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
Setting
temperature
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
6. HIGH POWER Mode
5. QUIET Mode
Remote Controller
SPECIAL REMARKS
‘‘DRY’’ Operation
Cooling Operation
SETTING THE TIMER
1. How to set the present time
SETTING THE TIMER CONTINUED
REPEAT timer
USING THE 1-HOUR OFF TIMER
TIPS FOR ENERGY SAVING
Setting procedure
Cancellation procedure
ADJUSTING THE AIRFLOW DIRECTION
OPERATION WITHOUT THE REMOTE CONTROLLER
CARE AND CLEANING
CARE AND CLEANING CONTINUED
How to remove the filter 1. Grasp both ends of the air
filter
Groove Pin Air intake grille
WIRED REMOTE CONTROLLER
CARE AND CLEANING CONTINUED
When using a footstool or the like, be careful not to let it tip over
Washing the grille with water
TROUBLESHOOTING BEFORE CALLING FOR SERVICE
OPERATING RANGE
Trouble
Possible Cause
SPECIFICATIONS
Model No
Indoor Unit
CS-MKS7NKU
APPENDIX B Operating Instructions
CS-MKS18NKU CS-MKS24NKU
CS-MKS18NKU
CS-MKS24NKU
Model No
Indoor Units
FEATURES
CONTENTS
SAFETY PRECAUTIONS
Simple One-touch Remote Controller
ELECTRICAL REQUIREMENTS
INSTALLATION LOCATION
SAFETY INSTRUCTIONS
Refrigerant gas leakage may cause fire
Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose
Remote Controller
NAMES OF PARTS
Refrigerant Tubes OUTDOOR UNIT Air Outlet
UNIT DISPLAY AND OPERATION BUTTON
REMOTE CONTROLLER DISPLAY
REMOTE CONTROLLER
REMOTE CONTROLLER CONTINUED
USING THE REMOTE CONTROLLER
REMOTE CONTROLLER CONTINUED
USING THE REMOTE CONTROLLER CONTINUED
OPERATION WITH THE REMOTE CONTROLLER
1. Operation
3. Fan Only
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
2. Adjusting the Fan Speed
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
4. Night Setback Mode
5. QUIET Mode
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
6. HIGH POWER Mode
Remote Controller
SPECIAL REMARKS
‘‘DRY’’ Operation
Cooling Operation
SETTING THE TIMER
1. How to set the present time
SETTING THE TIMER CONTINUED
REPEAT timer
USING THE 1-HOUR OFF TIMER
Setting procedure
Cancellation procedure
2. Operation together with the DAILY ON/OFF REPEAT Timer
ADJUSTING THE AIRFLOW DIRECTION
OPERATION WITHOUT THE REMOTE CONTROLLER
CARE AND CLEANING
CARE AND CLEANING CONTINUED
How to remove the filter 1. Grasp both ends of the air
filter
Groove Pin Air intake grille Air intake grille
WIRED REMOTE CONTROLLER
CARE AND CLEANING CONTINUED
TROUBLESHOOTING BEFORE CALLING FOR SERVICE
OPERATING RANGE
Trouble
Possible Cause
SPECIFICATIONS
Model No
Indoor Unit
CS-MKS18NKU
APPENDIX C INSTALLATION INSTRUCTIONS
CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU
INSTALLATION INSTRUCTIONS Split System Air Conditioner
Contents
NOTE External diameter of service port R410A 5/16
For Indoor Unit
SPECIAL PRECAUTIONS
When Transporting
When Installing…
In Case of Improper Installation
&KHFNFDUHIXOO\IRUOHDNVEHIRUHVWDUWLQJWKHWHVWUXQ
When Servicing
Others
1. General
1-1. Tools Required for Installation not supplied
1-2. Accessories Supplied with Unit Table
obtaining wire. Also, check
2. Installation Site Selection
1-5. Additional Materials Required for Installation
2-1. Indoor Unit
AVOID
2-2. Embedding the Tubing and Wiring
3. How to Install the Indoor Unit
trical wiring or conduits are
3-1. Remove the Rear Panel from the Unit
3-2. Make a Hole
3-3. Install the Rear Panel on the Wall
a If Wooden Wall
b If Block, Brick, Concrete or Similar Type Wall
Fig. 13a
3-4. Removing and Installing the Grille 3-4-1. Indoor unit types
How to remove the grille
How to replace the grille
3-4-2. Indoor unit types CS-MKS18NKU, CS-MKS24NKU
Fig. 19b-1
3-6. Wiring Instructions General precautions on wiring
3-5. Shape the Indoor Side Tubing
Fig. 26b
3-7. Wiring Instructions for Inter-unit Connections
Fig. 26a
WARNING Loose wiring may cause the terminal to overheat or result
How to connect wiring to the terminal a For Indoor Unit
b For Outdoor Unit For solid core wiring or F-cable
For stranded wiring
3-8. Mounting
Right-side tubing
Fig. 37a
Fig. 37b
Switching drain hose and drain cap
Left-side tubing
Drain hose
Drain cap
Do not supply power to the
tubing and wiring to the out
To unmount indoor unit
3-9. Drain Hose
Fig. 59c
4. How to Test Run the Air Conditioner
Fig. 59a Fig. 59b
5. Remote Controller Installation Position
6. Address Switch
6-1. Address Setting of the Remote Controller
7. Connecting a Home Automation Device
8. Installation Check Sheet
Page
DC1111-0