■Setting

Setting

Disable Filter Cleaning

To disable the filter cleaning permanently, follow steps 1 to 3 as shown below.

1 CHANGE FILTER CLEANING DEFAULT SETTINGPress and hold until you

Press and hold for more than 20 seconds. ON will blink on the display.*

2 Press once.1 hear 3 beeps (about 11

Press to select OFF.

3 2 You will hear 1 beep.*seconds).

Press to confirm the setting. CLEANING will disappears from the display.

Auto and timer filter cleaning are no longer valid.

Select ON in step 2 above to enable filter cleaning.

Hint

Manual filter cleaning is operable

by pressing Press 3 times until you . For detail, see manual filter cleaning page.

CHANGE FILTER CLEANING DEFAULT SETTING

• As a default setting, filter cleaning will run automatically once the air conditioner unit is turned off.

Press and hold until you

Press once.

1 hear 3 beeps (about 11

2 You will hear 1 beep.*

seconds).

 

Auto OFF/

 

ON button.

Press 3 times until you

 

 

3 hear 3 continuous beeps.*

4 Press to select your desired filter cleaning setting:

When you hear

Setting

1 beep

Filter cleaning will run automatically after the air conditioner

 

 

operation stops (air conditioner is turned off using remote control).

 

After the filter cleaning is completed, the air conditioner operation

 

 

will remain off.

2 beeps **

Filter cleaning will run automatically before the air conditioner

 

 

operation starts (air conditioner is either turned on using remote

 

 

control or turned on by the air conditioner timer).

 

After the filter cleaning is completed, the air conditioner operation

 

 

will start automatically.

3 beeps **

Filter cleaning will run automatically before the air conditioner

 

 

operation starts (air conditioner is turned on using remote control).

 

After the filter cleaning is completed, the air conditioner operation

 

 

will start automatically.

1 long beep

Filter cleaning will run automatically after the air conditioner

(default setting)

 

operation stops (air conditioner is either turned off using remote

 

control or turned off by the air conditioner timer).

 

 

After the filter cleaning is completed, the air conditioner operation will remain off.

*Use a sharp end object to press this button.

**The setting is valid only if the following conditions are fulfilled:

1.The air conditioner is turned off for at least 3 minutes.

2.The air conditioner has operated continuously for at least 2 hours in previous operation.