Panasonic CU-C24PKF-3, CU-C12PKF-3 To learn more, nanoe-G in-filterdeactivation, Operation mode

Models: CS-C12PKF-3 CS-C18PKF-3 CS-C24PKF-3 CU-C24PKF-3 CU-C18PKF-3 CU-C12PKF-3

1 12
Download 12 pages 45.47 Kb
Page 8
Image 8
To learn more...

To learn more...

Operation mode

COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.

DRY : Unit operates at low fan speed to give a gentle cooling operation.

nanoe-G in-filter deactivation

Depending on the unit’s accumulated operation time, nanoe-G in-filter deactivation may activate only once a day after the unit turned off.

To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly. This process only applicable when the unit is operated in COOL/DRY mode before turned off. Then, nanoe-G deactivates viruses/bacteria on the filter for 2 hours with fan stopped and louver closed.

Do not turn off the power supply during this operation. After power failure, this operation will not resume.

ECONAVI and AUTO COMFORT

AUTO

ECONAVI COMFORT or

The unit will start to initialise

The human activity sensor

and the sunlight sensor will

(for approximately 1 minute)

start to detect.

 

Note

AIR SWING When manual AIR SWING is selected, the ECONAVI and AUTO COMFORT operations will be cancelled.

Human activity sensor operation

ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.

Mode

Human

Low activity

Normal activity

High activity

Absent

 

 

+1 °C

 

 

+2 °C

COOL/DRY

Set

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human comfortable consistently.

Mode

Human

Low activity

Normal activity

High activity

Absent

 

 

+1 °C

 

 

+2 °C

 

Set

 

 

 

 

 

 

 

 

COOL/DRY

temperature

 

 

-1 °C

 

 

 

 

 

 

Set

 

 

+1 tap

 

 

Fan Speed

 

 

 

 

*During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.

**During human absence, maximum fan speed for COOL/DRY mode is medium fan.

8

Page 8
Image 8
Panasonic CU-C24PKF-3, CU-C12PKF-3 To learn more, nanoe-G in-filterdeactivation, Operation mode, ECONAVI and AUTO COMFORT