The human activity sensor will also scan for area of heat source and movement in a room.

Detection area

Human activity indicator

120º

 

7m

 

At left area

At center / multiple area

At right area

The unit judges human activity area for a few seconds before indicator updates. Based on area activeness horizontal airflow direction louver will adjust either fix at predetermined position or swing left/right periodically.

The human activity sensor performance is influenced by indoor unit location, movement speed, temperature range, etc.

The human activity sensor may:

-mistakenly detect an object with heat source & movement similar to human, such as pets, etc.

-mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.

Do not place large objects near the sensor and keep away heating units or humidifier from the sensor’s detection area. They may cause sensor malfunction.

Sunlight Sensor operation

ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.

Mode

Ambient condition

 

 

+1 °C

COOL/DRY

Set

temperature

 

ECONAVI is activated, the unit maintains set temperature until a high sunlight intensity is detected. The sunlight sensor detects sunlight intensity during weather or day/night changes, and the unit adjusts temperature.

• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.

Automatic Voltage Switcher (AVS)

When power supply is unstable, where the AC voltage supplied is below 185 V or above 260 V, AVS will switch off the outdoor unit to protect the compressor. During this condition, the AVS indicator will turn on.

 

Indicator

Indoor unit

Outdoor unit

POWER/AVS

Green

ON

ON

 

Orange

ON

OFF

Note: Room temperature may rise during AVS ON.

Operation conditions

Use this air conditioner under the following temperature range.

DBT : Dry bulb temperature

WBT : Wet bulb temperature

Temperature (°C)

 

 

Indoor

 

Outdoor

 

DBT

 

WBT

DBT

 

WBT

 

 

 

 

 

COOL

 

Max.

32

 

23

55

 

31

 

Min.

16

 

11

16

 

11

 

 

 

 