SAFETY PRECAUTIONS

Before doing repair work, please read the "SAFETY PRECAUTIONS" carefully and fully understand them.

The precautionary items here are divided into "Warning" and "Caution" items.

Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly,

are included in the "Warning" table.

However, even precautionary items identified as " Caution" also have the potential for serious consequences if not performed correctly.

Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them.

Symbol Indication

: This symbol indicates items to which we need to pay attention. In this triangle, a definite precautionary item is described.

: This symbol indicates the item to be prohibited.

In or close to this circle, a prohibited item is described.

: This symbol indicates the items requiring special attention or instruction. In or close to this circle, a prohibited item is described.

After doing repair work, perform a test run to confirm that there are no abnormalities. At the same time, explain the precautions in use to the user.

Warning

Before performing an overhaul, disconnect the power plug or power cable from the unit.

Performing the work with the power supplied to the unit, may cause an electric shock.

When repair work or circuit inspection that requires power supply for the air conditioner, is to be performed,

 

do not touch the charging section.

 

Doing so may cause an electric shock.

Prohibit

For the step-up capacitor attached to the electric section, perform the repair work after sufficiently discharging it. Insufficient capacitor discharge may cause an electric shock.

Do not perform repair work on the electric sections with wet hands.

Doing so may cause an electric shock.

Prohibit

Do not start or stop the air conditioner by means of connecting or disconnecting the power plug.

Doing so may cause an electric shock or fire.

Prohibit

When conducting repair work only use components included in the parts list for the corresponding unit and perform the work with the appropriate tools.

Incorrect or poor repair work may cause an electric shock or fire.

Never modify the unit.

Doing so may cause an electric shock or fire.

Prohibit

Perform all electric work according to local applicable regulations related to electrical equipment or interior wiring regulation and make sure to use the exclusive circuit.

Insufficient capacity to the electric circuit or defective arrangement results may cause an electric shock or fire.

Make sure to replace any power cable or lead wire showing any signs of scratch or deterioration.

Failure to do so may cause an electric shock, overheating or fire.

Make sure that there is no dust on or slack in the power plug and insert fully into the socket.

Dust or incomplete connections may cause an electric shock or fire.

Do not damage or process the power cord, as it may cause an electric shock or fire.

Prohibit

For the wiring between the indoor unit and outdoor unit, securely fix the specified cable onto the terminal plate. Poorly fixed wiring may cause a heat or fire.

After connecting the wiring between the indoor unit and outdoor unit, attach the terminal cover securely. Incomplete attachment of the terminal cover may cause overheating or fire.

2

Page 2
Image 2
Panasonic CS-KE18NB4UW, CU-KE12NK1, CU-KE18NKU, CS-KE12NB41, CZ-18BT1U service manual Safety Precautions

CZ-18BT1U, CS-KE12NB41, CS-KE18NB4UW, CU-KE18NKU, CU-KE12NK1 specifications

The Panasonic CS-KE18NB4UW and CU-KE12NK1, along with the CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU, represent a suite of advanced air conditioning solutions built with cutting-edge technologies designed to provide optimal comfort, energy efficiency, and air quality in various settings.

One of the standout features of this lineup is the inverter technology. Inverter air conditioners adjust the compressor speed to maintain the desired temperature efficiently. This leads to significant energy savings compared to traditional air conditioners, which tend to frequently cycle on and off, consuming more power. By continuously regulating the temperature, the Panasonic units not only save electricity but also prolong the lifespan of the compressor.

Another noteworthy characteristic is the nanoe™ technology integrated into some of these models. Nanoe™ technology uses hydroxyl radicals to purify the air, minimizing harmful bacteria and allergens. This makes the Panasonic units particularly suitable for users with allergies or respiratory issues, providing a cleaner and healthier indoor environment.

In terms of design, these models are sleek and compact, allowing them to fit seamlessly into any room decor, whether in a home, office, or commercial space. The quiet operation is another advantage, making them ideal for bedrooms and study areas where minimal noise is essential.

Furthermore, the CS-KE18NB4UW and CU-KE12NK1 offer a range of powerful cooling and heating capacities, making them versatile solutions for various climate conditions. The cold climate performance ensures consistent heating in colder regions, while the robust cooling capabilities make them perfect for hot summer months.

The user-friendly features include a smart remote control system, allowing users to adjust settings with ease from a distance. Some models are equipped with Wi-Fi capability, enabling integration with smart home systems for enhanced control and programmability.

In conclusion, the Panasonic CS-KE18NB4UW, CU-KE12NK1, CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU air conditioning units exemplify innovation and efficiency. With their inverter technology, air purification features, compact designs, and smart functionalities, they stand out as ideal choices for maintaining comfortable and healthy indoor environments throughout the year.