Count system setting
Press . “UP” or “DOWN” will begin
to flash. Next select (“UP”) or (“DOWN”).
●Press and hold the ( ) or () but- tons to vary the value continuously.
<Count System “UP” >
●Displays the count for the number of screws driven.
( | Set number | ) |
The settings are activated by pushing
.
●When the set number of screws is reached, the buzzer sounds and the count value resets to zero.
< Count System “DOWN” >
●Displays the count for the remain- ing number of screws to be driven.
( Set number )
●When the set number of screws to be driven is reached, the buzzer sounds and the count value resets to original set number.
3.The settings are activated by pushing
.
●The previous setting will be can- celled and replaced with the new setting.
4.To prevent changes in the set values due to operational errors.
● Turn the HOLD switch
to ON. | ON |
|
Convenient function settings (buzzer sound setting/double tightening counting prevention time setting)
Buzzer sound setting
1.Press for 2 or more seconds while the control panel is illuminated.
●Count display lamp “F1” is illumi- nated.
2.The buzzer sound can be selected
with when “F1” is illuminated.
Operation | Display | Sound Frequency |
| b3 | High pitched sound |
|
| (Approx. 4 kHz) |
| b2 | Medium pitched |
|
| sound (Approx. 3 |
|
| kHz) |
| b1 | Low pitched sound |
|
| (Approx. 2 kHz) |
| b0 | No sound (OFF) |
●If is pressed while in the buzzer mode, the buzzer sound saved from the previous setting is dis- played.
3.The settings are activated by pushing
.
4.To prevent changes in the set values due to operational errors.
● Turn the HOLD switch
to ON. | ON |
|
Double tightening counting preven- tion time setting
1.Press for 2 or more seconds while the control panel is illuminated.
●Count display lamp “F1” is illumi- nated.
2.Press again to illuminate “F2” and
select the time with .
Operation | Display | No. of | Following the |
seconds | screw count, | ||
| 30 | 3 | screw driving |
|
| seconds | within the set |
|
|
| number of |
| 1 | 0.1 | seconds is |
| not counted. | ||
|
| second | |
|
|
| |
| 0 | OFF |
|
●If is pressed while in the time mode, the time setting saved from the previous setting is displayed.
3.The settings are activated by pressing
.
4.To prevent changes in the set values due to operational errors.
● Turn the HOLD switch
to ON. | ON |
|
To change the screw count while in use
1.Release the hold switch.
2.Adjust the count value with .
● The displayed number of screws
- -