Specifications | FP2−CCU |
6.3Table of MEWTOCOL−COM Error Code
27 Frame Over Error:
•
•
Situation
The command and response exceed 118 bytes.
Example of error
This occurs when a WD command is sent, if the data being sent at one time exceeds 118 bytes.
•ERR LED on the FP2 Computer Communication Unit Lights
40 BCC Error:
•
•
Situation
Transmission error occurred in command data.
Example of error
This occurs if the calculation value of the BCC added to the command being sent is erroneous.
•ERR LED on the FP2 Computer Communication Unit Lights
41Format Error:
•Situation
Command message that does not match the transmission format was sent.
•Example of error
This occurs if the “#” and transmission destination are missing from the command being sent.
•ERR LED on the FP2 Computer Communication Unit Lights
42Not Support Error:
•Situation
An unsupported command was sent.
A command was sent to an unsupported destination.
•Example of error
This occurs if the command name is erroneous by the command which has been incorrectly notated .
•ERR LED on the FP2 Computer Communication Unit Off
6 − 6