FP2−CCU | Specifications |
6.1 Specifications
6.1Specifications
General Specifications
Item | Specifications |
|
|
Ambient temperature | 0 to 55 °C/32 to 131 °F |
|
|
Storage temperature | |
|
|
Ambient humidity | 30 to 85 % RH (at 25°C non−condensing) |
|
|
Storage humidity | 30 to 85 % RH (at 25°C non−condensing) |
|
|
Vibration resistance | 10 to 55 Hz, 1 cycle/min.: double amplitude 0.75 mm (0.03 in.), |
| 10 min. on 3 axes |
|
|
Shock resistance | Min. 98 m/s2, 4 times on 3 axes |
Noise resistance | 1000 Vp−p, 50 ns, 1 μs pulse widths (based on in−house measurements) |
Operating condition | Free of corrosive gases and excessive dust |
|
|
Computer Communication Unit Performance Specifications
Item | Specifications |
| |
|
|
|
|
Interface | Two RS232C ports |
| |
|
|
|
|
Transmission distance | Max. 15 m/49.212 ft *1 |
| |
Transmission speed (Baud rate) | 19,200/9,600/4,800 bits/s, selectable using DIP switch | ||
|
|
|
|
Communication method | Half duplex |
| |
|
|
|
|
Synchronous method | Start−stop synchronous method | ||
|
|
|
|
Transmission code | ASCII |
| |
|
|
|
|
Transmission data format | Stop bit: 1−bit |
| |
|
|
|
|
|
| Parity: Valid (odd) |
|
|
|
|
|
|
| Character bits: 7−bit/8−bit, selectable using DIP switch | |
|
|
|
|
Data transmission order | 0 bit first in units of characters |
| |
|
|
|
|
End terminal code | CR (0DH) |
| |
|
|
| |
Computer linking | Message | Header (%) to terminator (CR) | Once transmission rights from the |
|
|
| host computer are received, com- |
| Maximum message length | Max. 118 characters/frame | munication is started. The commu- |
| nication protocol is MEWTOCOL− | ||
|
| (including “%” and “CR”) | |
|
| COM. | |
|
|
| |
Current consumption | 60 mA or less (at 5 V DC) |
| |
|
|
| |
Weight | Approx. 120 g/4.233 oz |
| |
|
|
|
|
*1: The value is given as 15 m/49.212 ft. in the specifications, but if used in an environment with a high noise level, communication may be unstable. Check the conditions using the actual device.
Note
This unit does not support extension header (<). Use the Multi Communication Unit.
6 − 3