KX-FT21RS
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
Signal | Identification Signal Format | Function |
Training 1 | A fixed pattern is transmitted to the receiving side at a speed | |
|
| (2400 to 9600 bps) designated by DCS, and the receiving side |
|
| optimizes the automatic equalizer, etc., according to this signal. |
TCF | Sends 0 continuously for 1.5 seconds at the same speed as the | |
(Training Check) |
| training signal. |
CFR | X0100001 | Notifies the sending side that TCF has been properly received. If |
(Confirmation to Receive) |
| TCF is not properly received, FTT (Failure To Train) X0100010 is |
|
| relayed to the sender. The sender then reduces the transmission |
|
| speed by one stage and initiates training once again. |
Training 2 | Used for reconfirming the receiving side like training 1. | |
Image Signal | Refer to the next page. | |
RTC | Sends 12 bits (0...01 × 6 times) to the receiver at the same speed | |
(Return to Control) |
| as the image signal and notifies completion of transmission of the |
|
| first sheet. |
EOP | X1110100 | End of one communication |
(End of Procedure) |
|
|
MCF | X0110001 | End of 1 page reception |
(Message Confirmation) |
|
|
DCN | X1011111 | Phase E starts. |
(Disconnect) |
|
|
MPS | X1110010 | Completion of transmission of 1 page. If there are still more |
| documents to be sent, they are output instead of EOP. After MCF | |
|
| reception, the sender transmits an image signal of the second |
|
| sheet. |
| X1111100 | If there is an operator call from the sender, it is output after RTC. |
(Procedural |
|
|
PIP | X0110101 | This is output when an operator call is received. |
(Procedural Interrupt Positive) |
|
|