Useful Information
22
Liquid damage
Caution:
LTo avoid permanent damage, do not use a microwave oven to speed up
the drying process.
Registering the handset to the base unit
1{j/OK}
2{v}/{e}: “SETTING HSi {>}
3{v}/{e}: “REGISTRATIONi {>}
4{v}/{e}: “REGISTER HSi {>}
5Press and hold {x} on the base unit for about 5 seconds.
LIf all registered handsets start ringing, press {x} to stop, then start
again from step 1.
LThe rest of the procedure must be completed within 4 minutes.
6{v}/{e}: Select a base unit number. i {>}
7Wait until “BS PIN” is displayed. i Enter the base unit PIN (default:
0000”). i {>}
LIf you forget your PIN, contact your nearest Panasonic service centre.
LWhen the handset has been registered successfully, w stops
flashing.
LIf w is still flashing, start again from step 1.
Specifications
Number of channels:120 Duplex Chan nels
Frequency range:1.88 GHz to 1.90 GHz
Duplex procedure:
TDMA (Time Division Multiple Access)
Channel spacing:1,728 kHz
Bit rate:1,152 kbit/s
Modulation:
GFSK (Gaussian Frequency Shift Keying)
RF transmission power:
Approx. 10 mW (average power per channel)
Voice coding:ADPCM 32 kbit/s
Power source:220–240 V AC, 50/60 Hz
Power consumption:
Base unit:
Standby: Approx. 1.2 W
Maximum: Approx. 3.9 W
Charger*1:
Standby: Approx. 0.6 W
Maximum: Approx. 3.6 W
Operating conditions:
5 °C–40 °C, 20 %–80 % relative air humidity (dry)
Problem Cause/solution
Liquid or other form of
moisture has entered the
handset/base unit.
LDisconnect the AC adaptor and
telephone line cord from the base unit.
Remove the batteries from the handset
and leave to dry for at least 3 days.
After the handset/base unit are
completely dry, reconnect the AC
adaptor and telephone line cord. Insert
the batteries and charge fully before
use. If the unit does not work properly,
contact your nearest Panasonic service
centre.
TG1311_1312_1313NZ(e).book Page 22 Tuesday, September 16, 2008 4:28 PM