Replacing Brushes

Replacing Brushes

Card

Carte

Tarjeta

E-Clip

Bride en E Sujetador de E

Agitator Shaft

Right End Cap

Abre d’entraînement

Eje del agitador

Bouchon droit

 

Tapa del extremo

 

derecho

Agitator Pulley

Agitator Support

Support de l’agitateur

Poulie de l’agitateur

Soporte del agitador

Polea del agitador

 

Push Off

Pousser

Enpuje hacia fuera

Brush

Brosse

Cepillo

When the bristles on the agitator are worn so that they do not touch a card held across the lower plate, the brushes should be replaced.

Remove lower plate and agitator.

Remove the E-clip from agitator shaft and end cap.

Do not bend agitator shaft or lose E- clip or spacer.

Pull agitator shaft out of agitator body.

Pull, or pry out, agitator holder and agitator pulley.

Push each brush out of agitator body as shown.

Install new brushes by reversing procedure.

Reinstall agitator holder and agitator pulley completely.

Reinstall the agitator shaft, end cap and E-clip.

See exploded view for correct assembly of parts.

Position belt over agitator pulley on the agitator.

Reinstall agitator and lower plate.

- 42 -