BEFORE REQUESTING SERVICE

BEFORE REQUESTING SERVICE

PROBLEMWARNING Electrical Shock or Personal Injury Hazard

Disconnect the electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from cleaner suddenly starting.

Review this chart to find do-it-yourself solutions for minor performance problems. Any service needed, other than those described in these Operating Instructions, should be performed by an authorized service representative.

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

 

 

 

 

Cleaner will

1. Unplugged at wall outlet.

1.

Plug in firmly. Push ON-OFF

not run.

 

 

 

switch to ON.

 

2.

ON-OFF switch not turned on.

2.

Push ON-OFF switch to ON.

 

3.

Tripped circuit breaker/blown

3.

Reset circuit breaker or replace

 

 

fuse at household service panel.

 

fuse.

 

 

 

 

Poor job of dirt

1. Full or clogged dust bag.

1.

Change dust bag.

pickup.

2.

Broken belt.

2.

Replace belt.

 

 

3.

Clogged hose or nozzle.

3.

Clean hose or nozzle area.

 

4.

Hose not inserted fully.

4.

Insert hose.

 

5.

Worn agitator.

5.

Replace agitator.

 

6.

Hole in hose.

6.

Replace hose.

 

7.

Dust cover improperly installed.

7.

Properly install dust cover.

 

8.

Belt not installed on motor shaft.

8.

Install belt on motor shaft.

 

 

 

 

Dust escapes

1. Bag improperly installed.

1.

Properly install bag.

the paper bag.

2.

Bag torn.

2.

Replace bag.

 

 

 

 

 

Light will

1. Burned out light bulb.

1.

Replace light bulb.

not work.

 

 

 

 

 

 

 

 

 

- 40 -

Page 40
Image 40
Panasonic MC-V5209 Before Requesting Service, Problem, Possible Cause, Possible Solution, Cleaner will, not run, fuse