Panasonic MC-V5239 operating instructions Replacing Brushes

Models: MC-V5239

1 44
Download 44 pages 49.88 Kb
Page 30
Image 30
Replacing Brushes

Replacing Brushes

Card

Carte

Tarjeta

When the bristles on the agitator are worn so that they do not touch a card held across the lower plate, the brushes should be replaced.

Remove lower plate and agitator.

 

E-Clip

 

Bride en E

 

Sujetador

 

de E

Agitator Shaft

Right End Cap

Bouchon droit

Arbre d’entraînement

Tapa de extremo

Eje del agitador

derecho

Belt Pulley

Agitator Holder

Poulie de

Soporte del agitador

la courroie

Support de l'agitateur

Polea para

 

correa

 

Push Off

Pousser

Empuje hacia Brush

fueraBrosse Cepillo

Remove the E-clip from agitator shaft and end cap.

Do not bend agitator shaft or lose E- clip.

Pull agitator shaft out of agitator body.

Pull, or pry out, agitator holder and agitator pulley.

Push each brush out of agitator body as shown.

Install new brushes by reversing procedure.

Reinstall agitator holder and agitator pulley completely.

Reinstall the agitator shaft, end cap and E-clip.

See exploded view on page 32 for correct assembly of parts.

Position belt over agitator pulley on the agitator.

Reinstall agitator and lower plate.

- 30 -

Page 30
Image 30
Panasonic MC-V5239 operating instructions Replacing Brushes