Panasonic PT-FW100NTU Care and Replacement, Cleaning the projector, Before cleaning the projector

Models: PT-FW100NTU

1 62
Download 62 pages 1.47 Kb
Page 40
Image 40
Care and Replacement

Care and Replacement

Cleaning the projector

Before cleaning the projector

Switch off the MAIN POWER and disconnect the power plug from the wall outlet.

Unplug all the cables from the projector.

Cleaning the outer surface of the projector

Wipe off dirt and dust gently with a soft cloth.

If it is difficult to remove the dirt, soak a cloth in a neutral detergent diluted with water, wring the cloth well and then wipe the projector. Dry off the projector with dry cloth.

If you use a chemical treated wipe, follow the instructions supplied with it.

Cleaning the lens and front glass surface

Wipe off dirt and dust gently with a lint-free cloth.

Make sure no dirt or dust remains on the surface of the lens. It will be enlarged and projected onto a screen.

Replacing the ARF (Auto Rolling Filter)

Before replacing the ARF

Press the POWER button for at least 0.5 seconds or press twice to turn off the projector. Wit until the cooling fan stops and the POWER indicator turn to RED.

Disconnect the Power cord from the main socket. Prepare a Phillips-head screw driver.

Contact an Authorized Service Center to purchase a replacement ARF (ET-RFF100).

When to replace the ARF

ARF is consumable product and effects on ventilation. FILTER indicator will inform you of the replacement timing. You can check the remaining amount of the ARF in FILTER REMAINING menu.

NOTE:

See “FILTER REMAINING” on page 34.

See “FILTER indicator” on page 39.

Replacement procedure

Maintenance

1.Turn the projector upside down and place it gently on a soft cloth.

2.Use a Phillips-head screwdriver to loosen 3 ARF cover fixing screws until the screws turn freely and remove the ARF cover.

ARF cover fixing screw Cleaning the projectorBefore cleaning the projector

5.Attach the ARF cover and tighten the ARF cover fixing screws securely with a Phillips-head screwdriver.

ARF fixing screw

ARF

PUSH 押す

 

Cleaning the outer surface of the projector Clamp

Soft cloth

ARF cover

NOTE:

3.Use a Phillips-head screwdriver to loosen an ARF fixing screws and release the clamp, then slightly slide up the used ARF to remove.

4.Insert the new ARF into the compartment in correct direction and slightly push down until it clicks. Tighten the ARF fixing screws securely with a Phillips-head screwdriver.

If the ARF and/or ARF cover are attached incorrectly, the projector may not be turned on.

Do not switch the power on while the ARF cover removed.

When you replace the ARF unit, clean the compartment and/or the Air Exhaust port if you need to.

ENGLISH - 40

Page 40
Image 40
Panasonic PT-FW100NTU manual Care and Replacement, Cleaning the projector, Replacing the ARF Auto Rolling Filter, English