When the TEMP indicator and the LAMP indicator are illuminated
There are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.
LAMP indicator 


TEMP indicator 


TEMP indicator
Indicator | Illuminated (red) | Flashing (red) | |
display | (Lamp unit on) | (Lamp unit off) | |
|
|
| |
| The surrounding temperature or | The surrounding temperature or | |
| the temperature inside the | the temperature inside the | |
Problem | projector has become unusually | projector has become | |
high. | dangerously high, causing the | ||
|
| lamp unit to automatically shut | |
|
| off. | |
|
|
| |
Possible | B The ventilation holes may be covered. | ||
cause | B The ambient temperature in the place of use may be too high. | ||
B The air filter may be blocked. |
| ||
|
| ||
|
|
| |
| B Uncover the ventilation holes. |
| |
| B Set up the projector in a place where the temperature is | ||
| between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is | ||
| between 20% and 80% (with no condensation). [If you set the | ||
Remedy | “HIGHLAND” to “ON” (page 50), set up the projector in a place | ||
where the temperature is between 0 °C (32 °F) and 35 °C | |||
| |||
| (95 °F) and the humidity is between 20% and 80% (with no | ||
| condensation).] |
| |
| B Disconnect the mains lead by following the procedure on page | ||
| 28, and then clean the air filter. (Refer to page 56.) | ||
|
|
|
| LAMP indicator |
| ||
|
|
|
| |
Indicator | Illuminated (red) | Flashing (red) | ||
display | ||||
|
|
| ||
|
|
|
| |
| It is nearly time to | An abnormality has been detected in the lamp | ||
Problem | replace the lamp | circuit. |
| |
| unit. |
|
| |
|
|
|
| |
| B Does “REPLACE | B The power may | B There may be an | |
Possible | LAMP” appear on | have been turned | abnormality in the | |
the screen after | on straight away | lamp circuit. | ||
cause | ||||
the projector is | after it was turned | B The lamp unit may | ||
| ||||
| turned on? | off. | be blown. | |
|
|
|
| |
| B This occurs when | B Wait for a while | B Disconnect the | |
| the operation time | until the lamp unit | mains lead by | |
| for the lamp unit is | cools down before | following the | |
| nearing 2 250 | turning the power | procedure on | |
| hours. Ask your | back on again. | page 28, and then | |
| dealer or an |
| contact an | |
Remedy | Authorised |
| Authorised | |
| Service Centre to |
| Service Centre. | |
| replace the lamp |
| B Ask your dealer or | |
| unit. (page 57) |
| an Authorised | |
|
|
| Service Centre to | |
|
|
| replace the lamp | |
|
|
| unit. (page 57) | |
|
|
|
|
NOTE:
BBe sure to disconnect the mains lead by following the procedure given in “Turning off the power” on page 28 before carrying out any of the procedures in the “Remedy” column.
BIf the TEMP indicator is illuminated and the power turns off after the procedures in the “Remedy” column have been carried out, it means an abnormality has occurred. Please contact an Authorised Service Centre so that the necessary repairs can be made.
Care and maintenance