Options Adjustments

 

Options

2/3

 

 

Button lock

Off

 

Remocon User level

Off

 

ID select

0

 

 

Remote ID

Off

 

 

 

 

Serial ID

Off

 

Item

Effect

 

 

Adjustments

 

Off

MENU&ENTER

On

 

Off:

All the buttons at the bottom of the main unit can be used.

Button lock

MENU & ENTER:

 

 

 

Locks and

buttons on bottom face of main unit.

 

 

 

 

MENU

ENTER/

 

On: Locks all the button on bottom face of main unit.

 

Off

User1

User2

User3

 

 

 

Remocon

Off:

You can use all of the buttons on the remote control.

 

 

User1:You can only use

,

, ,

, ,

, ,

buttons on the remote control.

User level

User2:You can only use

,

, buttons on the remote control.

 

 

 

User3:Locks all the buttons on remote control.

 

 

 

Sets panel ID number when panel is used in “Remote ID” or “Serial ID”.

 

 

 

ID select

 

 

Set value range: 0 - 100

 

 

 

 

 

 

(Standard value: 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote ID

 

 

Off:

Disables ID remote control functions. You can use normal remote control operations.

 

 

 

Off

On

On:

Enable ID remote control functions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the panel ID Control.

 

 

 

Serial ID

Off

On

Off:

Disables external control by the ID.

 

 

 

 

On:

Enables the external control by the ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

3/3

 

 

 

 

 

 

 

 

 

Slot power

Off

 

 

 

 

 

 

 

V. lnstallation

Off

 

 

 

 

 

 

 

Rotate

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Slot Select

Slot1

 

 

 

 

 

 

 

 

 

 

 

 

Item

Effect

 

 

Adjustments

 

 

 

 

 

 

Off

Auto

On

 

 

 

 

 

 

Off:

Power is not transmitted to the slot power.

 

 

 

Slot Power

 

 

Auto: Power is transmitted to the slot power only when main power is on.

 

 

 

 

 

On:

Power is transmitted to the slot power when main power is on or in the standby state.

 

 

 

 

 

 

 

 

 

 

 

 

Note: In some cases, power is transmitted to the slot power when main power is on or in the standby

 

 

 

 

state regardless of the slot power setting.

 

 

 

 

 

 

Off:

Sets fan to the horizontal installation mode.

 

 

 

 

 

 

On:

Sets fan to the vertical installation mode.

 

 

 

V.Installation

Off

On

Notes:

 

 

 

 

 

 

 

 

• This functions when display is turned on.

 

 

 

 

 

 

 

 

 

 

 

 

• If the display is installed vertically, the power switch should be located at the bottom.

 

 

 

Rotate

 

 

Off:

Does not rotate the image.

 

 

 

Off

On

On:

Rotates the image 180 degrees.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Slot

 

 

Slot1

Slot2

Slot3

 

 

 

 

 

Selects the slot which communicates serial.

 

 

 

Select

 

 

 

 

 

 

 

Note: The setting of an external command can be set only from the fixed serial terminal (see page 11)

 

 

 

Normalization

When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again.

Press the

button on main unit together with

button on the remote control and hold for more than 5 seconds. The

“SHIPPING” menu is displayed and the lock is released when it disappears.

42

Page 42
Image 42
Panasonic TH-103PF9UK manual Normalization, Locks Buttons on bottom face of main unit, Off User1 User2 User3 Remocon