ON: Enables the PLAYBACK AUTO mode.

OFF: Disables the PLAYBACK AUTO mode.

5. PASSWORD

This item lets you select whether to permit free or limited access to the Setup menus. When PASSWORD is set to ON, the operator must enter the password to access the menus.

1.Move the cursor to the PASSWORD parameter.

2.Select ON or OFF by pressing the + or button. The initial factory setting is OFF.

5-1. Password registration

Enter a 4-digit password consisting of numbers from 1 to 9 (except 0).

ON1111-9999:

Password required to access the Setup menus.

1.Select ON by pressing the + or button.

2.Move the cursor to the desired (first) digit by press- ing the A or B button.

3.Select the desired number by pressing the + or button.

4.Repeat steps 2 and 3 until all digits are registered.

OFF: No password required to access the Setup menus (access is free).

5-2. Reply to password request

If PASSWORD parameter is set to ON, the operator is requested to type the password to access the Setup menus.

1.Press the MENU/ESC button for 2 seconds or more. The password inquiry screen prompts you to type the password.

2.Type the 4-digit password by pressing the CAMERA SELECT buttons 1 through 9, and the A or B button.

3.The Setup menu appears if the typed password is cor- rect. If a wrong password is typed, the screen displays “NG” and returns to the screen before the MENU/ESC button was pressed.

4.To retry repeat steps 1 and 2.

5-3. Changing the password

The password currently registered can be changed as fol- lows.

1.Press the MENU/ESC button for 2 seconds or more to display the password inquiry screen. Then type in the current password by pressing the CAMERA SELECT buttons, and the A or B button. The SETUP menu appears.

2.In the SYSTEM SETUP menu, select ON for the PASS- WORD parameter.

3.Move the cursor to the first (desired) digit by pressing the A or B button.

4.Select the desired number by pressing the + or but- ton.

5.Repeat step 3 and 4 until all digits are registered.

6.After registration the new password is required when the operator accesses the SETUP menus.

6.PWR ON MULTI

This parameter lets you select a multiscreen output pattern for your startup screen. When the power is turned on, the picture is displayed in the selected pattern.

1.Move the cursor to the PWR ON MULTI parameter.

2.Select 1-16 (1-9 only for WJ-FS309/FS409), SPOT SEQ or QUAD-4A to 4D, 9 screen, 16 screen, MLT-SEQ The initial factory setting is QUAD-4A.

1-16:Spot picture of selected channel is displayed.

SPOT SEQ: A sequence of spot pictures is displayed.

QUAD-4A to 4D: 4-segment screen

9 screen: 9-segment screen

16 screen: 16-segment screen

MLT-SEQ:Multiscreen sequence

7.PWR ON SPOT

This parameter lets you select a Spot output pattern for your startup screen. When the power is turned on, the pic- ture is displayed in the selected pattern.

1.Move the cursor to the PWR ON SPOT parameter

2.Select 1-16 (1-9 only for WJ-FS309/FS409) or SPOT SEQ.

The initial factory setting is 1.

1-16:Spot picture of selected channel is displayed.

SPOT SEQ: A sequence of spot pictures is displayed.