Camera Configuration (CAM CON- FIG)

This item lets you set numbers for the input from sys- tem cameras for RS-485 communication.

1.Move the cursor to CAM CONFIG with the C or D but- ton, then press the - or + button. The CAMERA CONFIG menu shown below will appear on the monitor screen.

COMMUNICATION SETUP

UNIT ADDRESS

1

CAM CONFIG

 

 

 

 

 

BAUD RATE

 

 

 

 

9600

DATA BIT

 

 

 

 

8

PARITY CHECK

NONE

STOP BIT

 

 

 

 

1

WAIT TIME

 

 

 

 

OFF

 

SETUP

ENABLE

CAMERA CONFIG

 

INPUT CH

 

CAM NO.

A CH

 

 

 

 

001

 

 

B CH

002

 

 

S-VIDEO

003

 

 

2.Move the cursor to the input parameter to be edited with the C or D button, then select a number with the

-or + button.

Select a parameter value between 001 and 128.

The factory default setting for each input is shown below.

A CH

001

B CH

002

S-VIDEO

003

Note: Make sure not to assign the same number to more than one system camera for RS-485 commu- nication.

3.Repeat the above procedure to edit other input.

4.After completing the settings, press the MENU button to return to the previous setup menu.

Baud Rate (BAUD RATE)

This item lets you set the transmission speed for RS-485 communication.

1.Move the cursor to the BAUD RATE parameter with the C or D button.

2.Select the desired transmission speed shown below with the - or + button.

2 400 4 800 9 600 19 200

The factory default setting is 9 600 bps.

Data Bit (DATA BIT)

This item lets you set the number of data bits for RS-485 communication.

The factory default setting is 8 bit and fixed.

Parity Check (PARITY CHECK)

This item lets you set the parity bit for RS-485 communica- tion.

1.Move the cursor to the PARITY CHECK parameter with the C or D button.

2.Select NONE, EVEN or ODD for parity check with the - or + button.

The factory default setting is NONE

Stop Bit (STOP BIT)

This item lets you set the number of stop bits for RS-485 communication.

1.Move the cursor to the STOP BIT parameter with the C or D button.

2.Select either 1 or 2 for number of stop bits with the - or + button.

The factory default setting is 1 bit.

Wait Time (WAIT TIME)

This item lets you set the waiting time in milli-seconds (ms) to retry after confirming that no data is received from the system controller for RS-485 communication.

1.Move the cursor to the WAIT TIME parameter with the C or D button.

2.Select OFF, 100, 200, 400, 1 000 ms for the wait time with the - or + button.

When no transmission is needed, select OFF. The factory default setting is OFF (no retry).

10

Page 10
Image 10
Panasonic WV-CM1780 Camera Configuration CAM CON- FIG, Baud Rate Baud Rate, Data Bit Data BIT, Parity Check Parity Check