SETUP PROCEDURES

This monitor offers various onscreen menus for setting user preferences.

In the COMMUNICATION SETUP Menu, you can set the parameters for communication between the System Controllers and the Monitors.

Displaying the Setup Menu

To display the Setup Menu, follow the procedure shown below.

1.Confirm that the cameras and peripherals are connect- ed correctly and securely.

2.Turn the power of the monitor on by pressing the POWER button.

3.Press the MENU button for 5 seconds or more.

At first the Display Setting menu described on page 11 appears, and then the COMMUNICATION SETUP menu shown below.

COMMUNICATION SETUP

UNIT ADDRESS

1

 

CAM CONFIG

 

 

BAUD RATE

9600

DATA BIT

8

 

PARITY CHECK

NONE

STOP BIT

1

 

WAIT TIME

OFF

SETUP

DISABLE

The following buttons are available in this Setup menu.

C: Moves the cursor down.

D: Moves the cursor up.

-:Selects the mode or parameter.

+: Selects the mode or parameter.

4.To finalize the settings and return to normal viewing, press the MENU button.

Setup Menu

As shown below, the Setup Menu has seven main sub- menus.

One of these, CAM CONFIG, is further divided into addi- tional submenus.

1.After selecting the Setup Menu on the monitor screen, move the cursor to SETUP DISABLE with the C or D button, then press the - or + button.

Display of SETUP ENABLE in the Setup menu indicates that setup is enabled.

COMMUNICATION SETUP

UNIT ADDRESS

1

CAM CONFIG

 

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

STOP BIT

1

WAIT TIME

OFF

SETUP

ENABLE

2.Move the cursor to the desired item with the C or D button.

3.Select the desired item parameter with the - or + button.

4.Press the MENU button to store the settings and return to normal viewing.

Unit Address (UNIT ADDRESS)

This item lets you set the unit address of the monitor in the system for RS-485 communication.

1.Move the cursor to the UNIT ADDRESS parameter with the C or D button.

COMMUNICATION SETUP

UNIT ADDRESS

1

 

CAM CONFIG

 

 

BAUD RATE

9600

DATA BIT

8

 

PARITY CHECK

NONE

STOP BIT

1

 

WAIT TIME

OFF

SETUP

ENABLE

2.Select the unit address number to be used for RS-485 communication with the - or + button.

Select a parameter value between 1 and 99. The factory default setting is 1.