33
Important:
If open wiring is conducted, be sure to use conduits and run the cables inside the tubes to
protect the cables from direct sunlight.
When connecting the conduit at the lateral or bottom position, any of the arrow marks on
the bracket shall be at the top.
When connecting the conduit upward, mount the camera attachment with the arrow posi-
tion on either left or right side.
<When connecting the conduit sideward or downward>
For installation on the wall, do not connect the conduit at the upper side to prevent water
from being stored in the bracket. If water remains inside, the dehumidifying device cannot
function properly.
Installation work shall be such that there is no intrusion of water into the architecture
through the conduits having been joined.
Connecting
conduit
Arrow mark
<When connecting the conduit upward>
FRONT TOP