Paradyne 3165 DSU/CSU manual Alarm Configuration Options, 10E±4

Models: 3165 DSU/CSU

1 18
Download 18 pages 1.87 Kb
Page 14
Image 14

Table 6. Alarm Configuration Options

Option

Factory 1

Factory 2

Comments/Description

 

 

 

 

 

Disab

Disab

Does not display alarm messages.

 

 

 

 

 

Modem

Modem

Sends alarm messages to Modem

 

port.

 

 

 

Alrm Msg:

 

 

 

Com

Com

Sends alarm messages to COM

 

 

port.

 

 

 

 

 

 

 

 

Both

Both

Sends alarm messages to both

 

ports.

 

 

 

 

 

 

 

 

Enab

Enab

 

SNMP Trap:

 

 

Sends SNMP traps.

Disab

Disab

 

 

 

 

 

 

 

Enab

Enab

Specifies whether the modem

TrapDisc:

 

 

connection will disconnect after a

Disab

Disab

 

trap is sent.

 

 

 

 

 

Enab

Enab

Provides the option to allow

DialOut:

 

 

automatic dial-out to send alarm

Disab

Disab

 

messages on MODEM port.

 

 

 

 

 

Enab

Enab

Specifies whether an outgoing call

Call Retry:

 

 

is retried on a busy or failed call

Disab

Disab

 

attempt.

 

 

 

 

 

1±4

1±4

The time (in minutes) to delay

Dial Delay:

5

5

between successive alarm

 

6±10

6±10

dial-outs or retry attempts.

 

 

 

 

 

None

None

The alternate dial-out directory to

AltDialDir:

use if a call to the primary number

1±5

1±5

 

cannot be completed.

 

 

 

 

 

 

 

 

10E±4

10E±4

 

 

 

 

 

 

10E±5

10E±5

 

 

 

 

 

Err Rate:

10E±6

10E±6

The error rate threshold for

(Excessive Error

 

 

Excessive Error Rate Alarm.

10E±7

10E±7

Rate)

 

 

 

 

 

 

10E±8

10E±8

 

 

 

 

 

 

10E±9

10E±9

 

 

 

 

 

12