Table 1. Port Configuration Options (1 of 2)

Option

Factory 1

Factory 2

Comments/Description

 

 

 

 

 

E530

E530

 

 

 

 

 

 

V.35

V.35

Selects the port type: EIA-530A,

Port Type:

 

 

RS449

RS449

V.35, RS449, or X.21.

 

 

 

 

 

 

 

 

X.21

X.21

 

 

 

 

 

 

Nx64

Nx64

Enables the port to either Nx56 or

Base Rate:

 

 

Nx56

Nx56

Nx64 rates.

 

 

 

 

 

 

 

 

Disab

Disab

 

 

 

 

 

 

V.54

V.54

Network-initiated DCLB, allows

Net DCLB:

 

 

DCLB to be controlled by inband

FT1

FT1

 

V.54 or FT1 (ANSI) codes.

 

 

 

 

 

Both

Both

 

 

 

 

 

 

Disab

Disab

 

 

 

 

 

 

DTLB

DTLB

Port-initiated Loopbacks, allows

Port LB:

 

 

Loopbacks to be initiated through

DCLB

DCLB

 

the port by the external DTE.

 

 

 

 

 

Both

Both

 

 

 

 

 

 

Disab

Disab

 

 

 

 

 

 

DTR

DTR

All ones sent to network (DTE) T1

All Ones:

 

 

RTS

RTS

when DTR or RTS interrupted.

 

 

 

 

 

 

 

 

Both

Both

 

 

 

 

 

Rcv Yellow:

None

None

Data port remains enabled, or is

 

 

disabled, on receiving Yellow on

(Received Yellow)

Halt

Halt

network T1.

 

 

 

 

 

 

Int

Int

Selects whether the transmitted

Tx Clock:

 

 

data clock is internal (TXC) or

Ext

Ext

 

external (XTXC).

 

 

 

 

InvertTxC:

Enab

Enab

Selects phase inversion of the

 

 

(Invert Tx Clock)

Disab

Disab

transmit clock (TXC).

 

 

 

 

 

 

 

Enab

Enab

Allows the data on the port to be

InvertData:

 

 

Disab

Disab

inverted.

 

 

 

 

 

 

 

4

Page 6
Image 6
Paradyne 3165 DSU/CSU manual Port Configuration Options 1