Paradyne 3165 DSU/CSU manual Management ± General Configuration Options 1

Models: 3165 DSU/CSU

1 18
Download 18 pages 1.87 Kb
Page 15
Image 15

Table 7. Management ± General Configuration Options (1 of 2)

Option

Factory 1

Factory 2

Comments/Description

 

 

 

 

 

Disab

Disab

Specifies whether the DSU/CSU

SNMP Mgt:

 

 

responds to SNMP session

Enab

Enab

 

requests.

 

 

 

 

 

 

 

 

Disab

Disab

Specifies whether the DSU/CSU

NMS Valid:

 

 

validates the IP address of an

Enab

Enab

SNMP manager attempting

 

 

access.

 

 

 

 

 

 

 

 

1

1

The number of management

Num Sec Mgrs:

systems authorized to send SNMP

2±10

2±10

 

messages to this unit.

 

 

 

 

 

 

 

 

Edit

Edit

Specifies the IP address for each

NMS n IP Adr:

 

 

NMS. This configuration option is

Clear

Clear

 

repeated for all n NMSs.

 

 

 

 

 

Read

Read

The type of access allowed for

NMS n ACS:

 

 

R/W

R/W

NMS n.

 

 

 

 

 

 

 

 

Edit

Edit

The SNMP system name for this

System Name:

 

 

Clear

Clear

device.

 

 

 

 

 

 

 

 

Edit

Edit

The SNMP system location for this

System Location:

 

 

Clear

Clear

device.

 

 

 

 

 

 

 

 

Edit

Edit

The SNMP system contact name

System Contact:

 

 

Clear

Clear

for this device.

 

 

 

 

 

 

 

 

Edit

Edit

A community name that is allowed

CommunityName1:

 

 

access to this device. Defaults to

Clear

Clear

 

public.

 

 

 

 

 

 

 

 

Read

Read

The type of access allowed for

Access 1:

 

 

R/W

R/W

community name 1.

 

 

 

 

 

 

 

 

Edit

Edit

A community name that is allowed

CommunityName2:

 

 

Clear

Clear

access to this device.

 

 

 

 

 

 

 

 

Read

Read

The type of access allowed for

Access 2:

 

 

R/W

R/W

community name 2.

 

 

 

 

 

 

 

 

Edit

Edit

The IP address needed to access

IP Adr:

 

 

Clear

Clear

the device.

 

 

 

 

 

 

 

 

Edit

Edit

The Subnet Mask needed to

NetMask:

 

 

Clear

Clear

access the device.

 

 

 

 

 

 

 

 

Edit

Edit

The IP address for the COM port

Com IP Adr:

 

 

Clear

Clear

when configured for SNMP.

 

 

 

 

 

 

 

13

Page 15
Image 15
Paradyne 3165 DSU/CSU manual Management ± General Configuration Options 1