Configuration Options
4-10 9820-A2-GB20-20
June 2000
Setting Up Management
FrameSaver units are already set up for SNMP management, with Community
Name 1 set to Public and Name 1 Access set to Read/Write. For remote sites,
other than the IP Address, this is all that is required.
Configuration
Management and Communication
General SNMP Management
See Table 4-12, General SNMP Management Options, for configuration
information. For the central site, local management between the unit and the
router must be set up, as well (see
Setting Up Local Management at the Central
Site
).

Setting Up Local Management at the Central Site

Set up a local management PVC between the central site unit and its router for
local management control by the end-user customer.
"Procedure
To set up management through the router:
1. Create a DLCI that will be used for management on the user data port.
Configuration
Data Ports
DLCI Records
2. Create a Management PVC using the user data port DLCI just created.
Configuration
Management and Communication
Management PVC
Minimally, enter the following options:
Name for the management PVC
Interface IP Address and Subnet Mask, if different from the Node’s
Primary Link for this Management PVC (the user data port)
Primary DLCI (i.e., the data port DLCI)
3. Save the configuration.
See Table 4-8, DLCI Record Options, and Table 4-11, Management PVC Options,
for configuration information.