Table 4. Communication Port Options (2 of 2)

Parity (Terminal Use Only)

Possible Settings: None, Odd, Even

Default Setting: None

Specifies the parity of the communication port.

Stop Bits (Terminal Use Only)

Possible Settings: 1, 1.5, 2

Default Setting: 1

Specifies the number of stop bits for the communication port.

Ignore Control Leads (Terminal Use Only)

Possible Settings: Disable, DTR

Default Setting: Disable

Specifies whether DTR is used.

Login Required (Terminal Use Only)

Possible Settings: Enable, Disable

Default Setting: Disable

Specifies if an ID and password are required to access the asynchronous terminal interface on the communication port. Login IDs are created with a password and access level.

Port Access Level (Terminal Use Only)

Possible Settings: Administrator, Operator

Default Setting: Administrator

Specifies the highest level of access allowed when accessing an ATI session through a Telnet session.

Inactivity Timeout (Terminal Use Only)

Possible Settings: Enable, Disable

Default Setting: Disable

Provides automatic logoff of a Telnet session.

Disconnect Time (Minutes) (Terminal Use Only)

Possible Settings: 1 ± 60

Default Setting: 5

Number of minutes of inactivity before the session terminates automatically. Timeout is based on no keyboard activity.

10

March 1999

7986-A2-GZ40-00

Page 10