Your D/AC-800 canbe rewired for operationabroad. Pleaserefer this conversionto a skilled electronicstechnician to avoid personalinjury or possiblehanDto the unit. There arehigh voltages prc:sentinside the chassisevenafter the power is turned ofT.

The main power supply printed circuit boardhastwo separatepower transformers. Nearby the transformersyou will find jumper wires which correspondto the various primary windings of each power transformer.

For 120V operation, a total of four jumper wires are connectedto the circuit board: two jumpers are connectedneareachtransformer,eachjumper has "120V" printed alongsideofit on the circuit board.

Folr 220-240V operation, only 2 jumpers are connectedto the circuit board; onejumper is colmectedneareachtmnsfonner, eachjumper has"220V" printed alongsideof it on the circuit board.

For 220-240Voperation,youmustalsodisconnectthefour 120Vjumpers.