Impedance

6 kΩ, minimum. Requires input current

 

(sourcing or sinking) of 0.111mA per volt of

 

user-supplied voltage Vi. (e.g., 1.11mA for

 

Vi=10V).

Status:

Check with the TIN or INFNC command.

Active Level:

Set by 6000 Series Controller/Indexer. Default is

 

active low, but can be changed to active high with

 

the INLVL command.

Input frequency

50 kHz (the maximum frequency is limited

 

practically to 500 Hz by the 2 ms update rate of

 

the 6000 Series.

 

 

Outputs

 

Voltage

Sourcing Current

 

Output voltage level is 2 volts less than the user-

 

supplied voltage Vo when sourcing up to 50mA.

 

(Vo – 2 VDC for 50 mA

 

e.g. for Vo=24V, output is at 22V)

 

Output voltage level is 2.5 volts less than the

 

user-supplied voltage Vo when sourcing up to

 

50mA.

 

(Vo – 2.5VDC for 300 mA

 

e.g. for Vo=24V, output is at 21.5V)

 

Sinking Current

 

Output voltage level is less than or equal to

 

0.4VDC when sinking up to 50mA.

 

(0.4 VDC for 50 mA)

 

Output voltage level is less than or equal to

 

2.5VDC when sinking up to 300mA.

 

(2.5 VDC for 300 mA)

Current

300mA maximum per output, continuous duty at

 

50°C ambient temperature

Status:

Check with the TOUT or OUTFNC command.

Active Level:

Default is active low, but can be changed to active

 

high with the OUTLVL command.

Rise Time

Load dependent; typically 40ns per 1000 pF

Fall Time

Load dependent; typically 40ns per 1000 pF

Installing the VM24

5

Page 9
Image 9
Parker Hannifin vm24 manual Outputs