Parkinson Cowan U02059 installation instructions S H E R A T O N, Location Of Appliance, less than

Models: U02059

1 40
Download 40 pages 3.29 Kb
Page 34
Image 34
LOCATION OF APPLIANCE

S H E R A T O N

LOCATION OF APPLIANCE

This appliance must not be installed in a bed-sitting room of volume less than 20m³ or in a bathroom or shower room. It is essential that the appliance is positioned as stated below (see Fig. 1a) i.e. shelves, wall cabinets and cooker hoods must be fitted a minimum of 787mm directly above the top of hotplate and 400mm above the hotplate when fitted in line with the outside of the appliance. If the units are intended to be fitted adjacent to the appliance but less than 400mm above the hotplate, then a minimum space of 100mm must be maintained between the sides of the unit and the appliance (see Fig.1b). Curtains must not be fitted immediately behind the appliance or within 150mm of the sides of the hotplate. If fitted next to or between two base units a minimum space of 1mm must be left between each unit and the sides of the appliance. The levelling feet fitted to the appliance will achieve a nominal height to hotplate trims of 900mm - 2mm +20mm.

400

787

787

100 less than

400

Fig.1a

All dimensions in mm

Fig.1b

34

Page 34
Image 34
Parkinson Cowan U02059 installation instructions S H E R A T O N, Location Of Appliance, less than