(because it originates after the framer) and is intended to be evaluated only by another Processor. If the units are transmitting data and the pattern generator is enabled on one end of the link, the far end will begin receiving unframed packets and assume that the line has gone down. During test modes, the pattern gen- erator is forced to time out before it can cause the DSL link to go down.
Loop Control This part of the Processor is used to control Remote Loopback test mode. In a Remote Loop, the 511/511/E data is looped back to the line and to the remote unit over the DSL span.
Restart Procedure The restart procedure is in place to allow the
and Time Outs units to
Test Mode Timing
Item |
| Elapsed Time (seconds) |
Start Up | 50 | |
Data Mode | 4 |
|
511/511E Generator Enabled | 60 | (The generator will stop after 45 seconds.) |
Remote End of an RDL | 60 |
|
511/511E Time Out | 45 | (The pattern generator will automatically turn |
| off after 45 seconds. The ER LED will flash until | |
| the user turns off the 511/511E switch.) |
Symbol Indicators
This symbol designates the origination or the termination of a data path. The direction of the arrow connected distinguish the two data paths.
This symbol designates an invalid data path. If there is data present it should be ignored.
15 | 16 |