4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the CopperLINK line. The following tables describe the configuration for the 2168B.

Table 1: 2168B Firmware Configuration

 

 

 

 

S1-1

 

S1-2

 

S1-3

 

S1-4

Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Master/

 

 

 

 

Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

Slave

 

 

 

 

 

 

 

 

 

 

 

 

 

(CPE)

 

4/1, 9/1, 16/2, 6/6, 10/10, 15/15

 

 

 

 

 

 

 

 

 

OFF

 

 

Master

 

Rate Control (See table below).

 

 

 

 

(CO)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1-2

 

S1-3

 

 

S1-4

 

Rate

 

 

 

 

 

 

 

(DS/US)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

 

OFF

 

4/1

 

 

 

ON

 

OFF

 

 

OFF

 

9/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

ON

 

 

OFF

 

16/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

 

 

OFF

 

6/6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

 

ON

 

10/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

 

 

ON

 

15/15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*. DS = Downstream, US = Upstream

5.0 OPERATION

Once the Model 2168Bs are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors.

5.1 POWER UP

Before applying power to the Model 2168B, please review section 3.3, “Connecting Power” on page 12 to verify that the unit is connected to the appropriate power source.