Be careful when using this feature. If you forget what the control characters were changed to, print a test label. The test label lists the current control characters. See "Printing a Test Label," in Chapter 8 for more information.

D e f i n i n g t h e C o m m u n i c a t i o n S e t t i n g s P a c k e t

Use the communication settings packet (F) to set the baud rate, word length, stop bits, parity, and flow control for serial communications. To set parallel communications, see "Using Parallel Communications." Changing the communication settings takes approximately two seconds. Communications sent during this interval will be lost. Make sure the host communication values match the values on the printer.

Syntax {I,F,baud,word_length,stop_bits,parity, flow_control p }

F1. F

Communication Settings Packet

F2. baud

Baud Rate. Options:

 

 

 

0

1200

3

9600 (default for all printers)

 

1

2400

4

19200

 

2

4800

5

38400

F3. word_length Word Length. Options:

07-bit word length

18-bit word length (default for all printers)

F4. stop_bits Stop Bits. Options:

01-stop bit (default for all printers)

12-stop bits

F5. parity

Parity. Options:

0None (default for all printers)

1ODD parity

2EVEN parity

F6. flow_control Flow Control. Options:

 

 

0

None

2

(CTS)

1

DTR (default

3

XON/XOFF

 

for all printers)

 

 

NOTE: If you use the DOS COPY command to download your formats, set "Flow Control" to DTR (not XON/XOFF).