b wire gauge
CCTM owner’s manual
stranded cable length | wire gauge |
|
| power loss | |
| 8 Ω load | 4 Ω load | 2 Ω load | ||
5feet |
| ||||
18AWG | 0.81% | 1.61% | 3.2% | ||
16 | 0.51 | 1.02 | 2.0 | ||
| |||||
| 14 | 0.32 | 0.64 | 1.28 | |
| 12 | 0.20 | 0.40 | 0.80 | |
| 10 | 0.128 | 0.25 | 0.51 | |
10feet | 18AWG | 1.61% | 3.2% | 6.2% | |
| 16 | 1.02 | 2.0 | 4.0 | |
| 14 | 0.64 | 1.28 | 2.5 | |
| 12 | 0.40 | 0.80 | 1.60 | |
| 10 | 0.25 | 0.51 | 1.01 | |
40feet | 18AWG | 6.2% | 11.9% | 22% | |
| |||||
| 16 | 4.0 | 7.7 | 14.6 | |
| 14 | 2.5 | 5.0 | 9.6 | |
| 12 | 1.60 | 3.2 | 6.2 | |
| 10 | 1.01 | 2.0 | 4.0 | |
80feet | 8 | 0.60 | 1.20 | 2.4 | |
18AWG | 11.9% | 22% | 37% | ||
| |||||
| 16 | 7.7 | 14.6 | 26 | |
| 14 | 5.0 | 9.6 | 17.8 | |
| 12 | 3.2 | 6.2 | 11.8 | |
| 10 | 2.0 | 4.0 | 7.7 | |
| 8 | 1.20 | 2.4 | 4.7 |
p.18