9

2 3

1

6

5

4

7

8

10

11

 

Mono Bi-Amp Operation (sub woofer & mid/high enclosure)

 

Set AMP MODE switch

 

to STEREO.

1.

1

 

Set the channel A AMP FUNCTION switch

 

to HIGH PASS.

2.

2

3.Turn on the channel A LOW CUT 3 .

4.

Set channel A LOW CUT frequency adjustment knob

4

to match the low frequency cut-off or the -3 dB down point

 

of the sub woofer. (If you don’t know this specification‚ set it for 40 Hz.)

5.Set the channel A CROSSOVER frequency adjustment knob 100–150 Hz).

5

to the desired crossover frequency (usually

6. Set the channel B AMP FUNCTION switch 6 to FULL RANGE.

7.Plug a short shielded cable into the high pass/full range output of channel A

8.

Connect the other end of the same cable to the channel B input

8

.

9.Connect the Mono program signal to the channel A input 9 .

10.

Connect the sub woofer(s) (in parallel) to the channel A output

10

.

 

 

11.

Connect the mid/high enclosure(s) (in parallel) to the channel B output

 

.

11

7

.

14

Page 14
Image 14
Peavey CS2000H, 12/0280304941 manual To Stereo