Operating Precautions

Make sure the mains voltage is correct and is the same as that printed on the rear of the amplifier. Damage caused by connecting the amplifier to improper AC voltage is not covered by any warranty. See the Connecting Power section for more information on voltage requirements.

Note: Always turn off and disconnect the amplifier from mains voltage before making audio connections. Also, as an extra precaution, have the attenuators turned down during power-up.

Although the CS 2000H amplifier has RampUpcircuitry, which raises the signal level gradually after the output relay closes, it is always a good idea to have the gain controls turned down during power-up to prevent speaker damage if there is a high signal level at the inputs. Whether you buy or make them, use good-quality connections, input cables and speaker cables, along with good soldering technique, to ensure trouble-free operation. Most intermittent problems are caused by faulty cables.

Consult the Wire Gauge Chart (below) to determine proper gauges for different load impedances and cable lengths. Remember that cable resistance robs amplifier power in two ways: power lost directly to resistance (I2R loss), and by lowering the total load impedance. Also make sure the mode switch is correctly set for the desired application. See Sections on Stereo, Parallel and Bridged Mono operation for more information.

 

 

 

 

 

 

W I R E

G A U G E

C H A R T

 

 

 

 

 

Cable Length

Stranded Wire Gauge

Power Loss into

Power Loss into

Power Loss into

(In Feet)

 

(AWG)

8 Ohms (%)

4 Ohms (%)

2 Ohms (%)

 

 

 

 

 

 

 

 

 

 

 

 

5

 

18

.79

1.58

3.16

 

 

16

.50

1.00

2.00

 

 

14

.31

.62

1.24

 

 

12

.20

.40

.80

 

 

10

.125

.25

.50

 

 

 

 

 

 

10

 

18

1.58

3.16

6.32

 

 

16

1.00

2.00

4.00

 

 

14

.62

1.25

2.50

 

 

12

.40

.80

1.60

 

 

10

.25

.50

1.00

 

 

 

 

 

 

40

 

18

8.00

12.60

25.20

.

 

16

4.00

8.00

1.60

 

 

14

2.50

5.00

10.00

 

 

12

1.60

3.20

6.40

 

 

10

1.00

2.00

4.00

 

 

8

.625

1.25

2.50

 

 

 

 

 

 

80

 

16

8.00

16.00

32.00

 

 

14

5.00

10.00

20.00

 

 

12

3.20

6.40

12.80

 

 

10

2.00

4.00

8.00

 

 

 

 

 

 

5