Peavey ICS 4200 user manual Thermal Emission

Models: ICS 4200

1 56
Download 56 pages 49.07 Kb
Page 17
Image 17
Thermal Emission

Current Consumption (Multiply current by 0.5 for 230 V units)

 

Rated power

15.4 A (4 Ohms)

13.2 A

 

9.9 A (8 Ohms)

 

1/3 power

9.9 A (4 Ohms)

8.6 A

 

6.3 A (8 Ohms)

 

1/8 power

6.6 A (4 Ohms)

5.8 A

 

4.2 A (8 Ohms)

 

Idle

0.4 A

0.7 A

 

 

 

Thermal Emission

 

 

1/3 power

3147 BTU/hr (4 Ohms)

2614 BTU/hr

 

1990 BTU/hr (8 Ohms)

 

1/8 power

2364 BTU/hr (4 Ohms)

2036 BTU/hr

 

1500 BTU/hr (8 Ohms)

 

 

 

 

Controls

Front: 4 channel input signal attenuators‚ AC switch

Rear: 2 x 4 DIP switches for input module assign‚ 2 output mode switches

Indicator LEDs

4 clip‚ 4 signal‚ 1 power

Protection

Over-temperature‚ DC‚ turn on/off transients‚ subsonic‚ incorrect load‚ short-circuit

Connectors

Input: Four 3-position Euro-style detachable terminal blocks‚ two ports for MMAinput modules

Output: Two 4-position barrier strips

Construction

16-gauge steel-reinforced with 12-gauge rack ears

Dimensions

Height: 3.50" (8.84 cm); 2 EIA rack spaces

Width‚ front: 19.00" (48.26 cm)

Width‚ rear: 17.00" (43.18 cm)

Overall depth: 17.05" (43.31 cm)

Mounting depth: 16.63" (42.24 cm) behind front rack ears

Weight

40 lbs. (18.1 kg)

Power Requirements

100‚ 120‚ 230–240 Vac‚ 50–60 Hz

Test Conditions

120Vac‚ 60 Hz line input voltage maintained All channels operating unless otherwise noted

(Due to our efforts for constant improvements‚ features and specifications listed herein are subject to change without notice.)

17

Page 17
Image 17
Peavey ICS 4200 user manual Thermal Emission