6 of 14 ISSUED:07-25-11 SHEET #: 125-9225-1
J
K
g1.4
CINDERBLOCK
SOLIDCONCRETE
C
Installation to Solid Concrete or Cinder Block
• WheninstallingPeerlesswallmountsoncinderblock,verifythatyouhaveaminimumof1-3/8"(35mm)ofactual
concretethicknessintheholetobeusedfortheconcreteanchors.Donotdrillintomortarjoints!Besuretomount
inasolidpartoftheblock,generally1"(25mm)minimumfromthesideoftheblock.CinderblockmustmeetASTM
C-90specications.Itissuggestedthatastandardelectricdrillonslowsettingisusedtodrilltheholeinsteadofa
hammerdrilltoavoidbreakingoutthebackoftheholewhenenteringavoidorcavity.
• Concretemustbe2000psidensityminimum.Lighterdensityconcretemaynotholdconcreteanchor.
• Makesurethatthewallwillsafelysupportfourtimesthecombinedloadoftheequipmentandallattachedhardware
andcomponents.
WARNING
1
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
drywall
plaster/
drywall
concrete concrete
1
3
2
KDrillholesandinsertanchors(K).
Placeplate(AA)overanchors(EE)andsecurewithscrews(DD).
Tightenallfasteners.
CK Jconcrete
surface
• Tightenscrewssothatwallplateisrmlyattached,
butdonotovertighten.Overtighteningcandamage
screws,greatlyreducingtheirholdingpower.
• Nevertighteninexcessof80in.•lb(9N.M.).
• Alwaysattachconcreteexpansionanchorsdirectly
toload-bearingconcrete.
• Neverattachconcreteexpansionanchorsto
concretecoveredwithplaster,drywall,orother
nishingmaterial.Ifmountingtoconcretesurfaces
coveredwithanishingsurfaceisunavoidable),
thenishingsurfacemustbecounterboredas
shownbelow.Besureconcreteanchorsdonot
pullawayfromconcretewhentighteningscrews.If
plaster/drywallisthickerthan5/8"(16mm),custom
fastenersmustbesuppliedbyinstaller.
WARNING
Makesurethatwallarmbracket(C)islevel,useitas
atemplatetomarkfourmountingholes.Drillfour5/16"
(8mm)dia.holestoaminimumdepthof2.5"(64mm).
Insertconcreteanchors(K)inholesushwithwallas
shown(right).Placewallarmbracketoveranchorsand
securewith#14x2.5"screws(J).Level,thentightenall