C2406M-F (4/04) 7

REINSTALL CAMERA MODULE

1. Reinstall the camera module. Refer to Figure 8. Make sure the top of the camera is oriented
properly. On the lens housing, look for the label that says TOP.
WARNING: To prevent damage to the camera or lens, the camera must be
installed in the proper hole of the mounting bracket. If the camera is not installed in
the correct hole, the window of the enclosure may be forced against the lens.
MOUNT CAMERAS WITH
2.9 AND 3.6 MM LENSES
MOUNT CAMERAS WITH
6, 8, AND 12 MM AND
VARIFOCAL LENSES
Figure 8. Camera Installation
2. Reconnect the electrical connections. If you do not need the heater, do not plug in the four-pin
heater connector with red, orange, and black wires.

ADJUST POSITION

1. Turn on power to the camera and monitor.
CAUTION: Heater elements could be
hot! When camera power is on, use
caution when adjusting the camera.
This applies to all models.
2. Varifocal Lens Only – Loosen the focal length
and focus locking screws (refer to Figure 9). Adjust
according to scene detail. Retighten the screws.
3. Adjust the position of the camera.
4. Adjustable Mounting Pattern Only – Refer to
Figure 10. Adjust the angle of the base and tighten
mounting hardware. If the watertight mounting
plate is installed, remove the base, adjust the
mounting plate, and reinstall the base.

REPLACE COVER

Place the cover of the ICS200 onto the base of the unit.
Use the screwdriver bit (provided) and tighten the three
tamperproof screws.
VARIFOCAL LENS
LOCKING
SCREWS
Figure 10. Adjustable Mounting Pattern
Figure 9. Varifocal Lens Adjustment