5.0 SPECIFICATIONS

NOTE: It is not recommended using 24 VAC in applications requiring heat- ers/blower because of the excessive current draw that may exceed Class 2 transformer applications.

ELECTRICAL

Enclosure Back Box

Input Voltage:

24 VAC or 120 VAC

Power Requirements

Receiver/Driver:

48 vA for 24 VAC and 120 VAC dome drives

Blower

 

continuous duty:

One (1) at 30 cfm, 1.92 watts, 24 VDC

 

One (1) at 33 cfm, 6.7 watts, 120 VAC 60 Hz

 

One (1) at 27 cfm, 8.9 watts 230 VAC 50 Hz

Heaters

 

24 VAC:

120 watts total

120 VAC:

135 watts total

230 VAC:

105 watts total

 

Thermostatically controlled; activates ON at 40°F (4.4°C) and

 

OFF at 60°F (15.56°C)

Power cord:

Not supplied; use 3-wire grounded, 18 Awg minimum for 120 or

 

230 VAC supply input

Power cable:

Not supplied: must conform to local and national electrical

 

codes

GENERAL

 

Enclosure

 

Environment:

Indoor or outdoor (depending on model ordered)

Dimensions:

See Figures 12 and 13

Construction

 

Back box:

Aluminum

Cap:

Aluminum

Bezel:

Aluminum

Trim Ring:

ABS/aluminum

Finish:

The following are standard colors; consult factory for optional

 

colors

Outdoor

 

Pendant

Light gray

Indoor

 

Suspended/

 

Hard Ceiling

White (back box) and eggshell white (faceplate, trim ring and

 

bezel)

Pendant

Black

Temperature Range

Indoor models: 32° to 120°F (0° to 48.89°C)

Outdoor models: -10°to 120°F (-23.33°to 48.89°C)

(Design and product specifications subject to change without notice.)