3.2.2 Hard-Wire or Remote Receiver/Driver

Refer to Figures 6 and 7 for wiring diagrams.

Refer to Table A for the type of video coaxial cable to use.

On models for suspended ceilings or hard ceilings, a plate is provided on the top of the back box with 1/2" and 3/4" conduit knockouts.

If your back box has a power switch, make sure it is off before wiring power to the back box.

A minimum of eleven (11) conductors plus coax are required for pan/tilt, motorized zoom lens and camera power. Dome drives with presets (PP) require an additional six (6) conductors for Type D or seven (7) conductors for Type E. The above does not include the conductor requirements for heaters/blower which will need an addi- tional two (2) plus ground.

The following cable distances are approximate and does not account for heaters/ blower.

Calculations are based on a 10% cable loss with both motors running.

Dome Drive

 

 

Model Type

 

 

 

 

 

 

 

 

Non-Preset Models

 

 

 

 

Type B & C

 

11 Conductors

12 Conductors*

 

 

 

 

 

 

 

 

Preset Non-SL Models

 

 

 

 

Type D

 

17 Conductors

18 Conductors*

 

 

 

 

 

 

 

 

Preset SL Models

 

 

 

 

Type E

 

18 Conductors

19 Conductors*

 

 

 

 

 

20 Awg

 

153 ft

(46.6 m)

281 ft (85.6 m)

18 Awg

 

244 ft

(74.3 m)

447 ft (136.2 m)

16 Awg

 

387 ft (117.9 m)

710 ft (216.4 m)

 

 

 

 

 

* Using 2-conductor common.

 

 

 

A relay box (RB24) for use with a hardwire control only is available to extend the operating distance (control to relay box) up to 15,000 ft over 18 Awg wire.

The following cable sizes are the minimum recommended for use with the heaters/ blower kit at the wattage and voltage listed.

122 watts @ 24 VAC

 

20 Awg

23 ft

(7 m)

18 Awg

37 ft (11.2 m)

16 Awg

58 ft (17.6 m)

127 watts @ 120 VAC

 

20 Awg

558 ft

(170 m)

18 Awg

888 ft

(270.6 m)

16 Awg

1,410 ft

(429.7 m)

129 watts @ 230 VAC

 

20 Awg

2,020 ft

(615.7 m)

18 Awg

3,213 ft

(979.3 m)

16 Awg

5,100 ft

(1,554.4 m)

Proceed to Section 3.3, DOME DRIVE INSTALLATION.